TY - JOUR
T1 - Valve-in-valve transcatheter aortic valve implantation with CoreValve/Evolut R© for degenerated small versus bigger bioprostheses
AU - Scholtz, Smita
AU - Piper, Cornelia
AU - Horstkotte, Dieter
AU - Gummert, Jan
AU - Ensminger, Stephan M.
AU - Börgermann, Jochen
AU - Scholtz, Werner
N1 - Publisher Copyright:
© 2018, Wiley Periodicals, Inc.
Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2018/6
Y1 - 2018/6
N2 - Objectives: We present our single center experience with Medtronic CoreValve and Evolut R regarding procedural outcome and 3 years follow-up in patients with degenerated bioprostheses. Methods: From 1645 patients who underwent transfemoral TAVI at our institution between February 2009 and December 2016, 37 patients with degenerated bioprosthesis were treated with Medtronic CoreValve/Evolut R. All data concerning baseline characteristic, procedural outcomes and follow-up were entered into a dedicated database. Results: Mean age was 83.9 ± 4.4 years and patients showed an average logistic EuroSCORE of 33.2 ± 16.7%. Successful ViV deployment was achieved in all cases, a permanent pacemaker was implanted in 16.2%, no periinterventional stroke and no coronary obstruction occurred. Mortality at 30 days was 2.7%, at 1-year follow-up 5.7% and at three years 13.5%. Depending on bioprosthesis size <23 mm versus ≥23 mm echocardiographic mean gradients post implantation were significantly higher in the smaller bioprostheses, 22.8 mmHg ± 9.4 mmHg versus 15.1 ± 7.1, P = 0.013. Conclusion: ViV-TAVI with CoreValve/R is demonstrated to be safe and effective in terms of no coronary obstruction and very low mortality up to 3 years despite slightly higher mean transprosthetic gradients especially in very small bioprostheses.
AB - Objectives: We present our single center experience with Medtronic CoreValve and Evolut R regarding procedural outcome and 3 years follow-up in patients with degenerated bioprostheses. Methods: From 1645 patients who underwent transfemoral TAVI at our institution between February 2009 and December 2016, 37 patients with degenerated bioprosthesis were treated with Medtronic CoreValve/Evolut R. All data concerning baseline characteristic, procedural outcomes and follow-up were entered into a dedicated database. Results: Mean age was 83.9 ± 4.4 years and patients showed an average logistic EuroSCORE of 33.2 ± 16.7%. Successful ViV deployment was achieved in all cases, a permanent pacemaker was implanted in 16.2%, no periinterventional stroke and no coronary obstruction occurred. Mortality at 30 days was 2.7%, at 1-year follow-up 5.7% and at three years 13.5%. Depending on bioprosthesis size <23 mm versus ≥23 mm echocardiographic mean gradients post implantation were significantly higher in the smaller bioprostheses, 22.8 mmHg ± 9.4 mmHg versus 15.1 ± 7.1, P = 0.013. Conclusion: ViV-TAVI with CoreValve/R is demonstrated to be safe and effective in terms of no coronary obstruction and very low mortality up to 3 years despite slightly higher mean transprosthetic gradients especially in very small bioprostheses.
UR - http://www.scopus.com/inward/record.url?scp=85042529091&partnerID=8YFLogxK
U2 - 10.1111/joic.12498
DO - 10.1111/joic.12498
M3 - Journal articles
C2 - 29490430
AN - SCOPUS:85042529091
SN - 0896-4327
VL - 31
SP - 384
EP - 390
JO - Journal of Interventional Cardiology
JF - Journal of Interventional Cardiology
IS - 3
ER -