TY - JOUR
T1 - Transjugular Portosystemic Stent Shunt
T2 - Impact of Right Atrial Pressure on Portal Venous Hemodynamics Within the First Week
AU - Pitton, Michael Bernhard
AU - Weinmann, Arndt
AU - Kloeckner, Roman
AU - Mittler, Jens
AU - Ruckes, Christian
AU - Düber, Christoph
AU - Otto, Gerd
N1 - Publisher Copyright:
© 2021, The Author(s).
PY - 2022/1
Y1 - 2022/1
N2 - Purpose: Porto-systemic pressure gradient is used to prognosticate rebleeding and resolution of ascites after TIPS. This study investigates the reliability of portal pressure characteristics as quantified immediately after TIPS placement and at short-term control. Patients and Methods: Portal venous pressure (PVP) and right atrial pressure (RAP) were prospectively obtained before and after TIPS as well as ≥ 48 h after TIPS procedure. Porto-systemic pressure gradients (PSG) and pressure changes were calculated. A multivariate regression analysis was performed to predict portal hemodynamics at short-term control. Results: The study included 124 consecutive patients. Indications for TIPS were refractory ascites, variceal bleeding or combinations of both. Pre- and post-interventional PSG yielded 16.4 ± 5.3 mmHg and 5.9 ± 2.7 mmHg, respectively. At that time, 105/124 patients (84.7%) met the target (PSG ≤ 8 mmHg). After 4 days (median), PSG was 8.5 ± 3.5 mmHg and only 66 patients (53%) met that target. In patients exceeding the target PSG at follow-up, PVP was significantly higher and RAP was lower resulting in the increased PSG. The highly variable changes of RAP were the main contributor to different pressure gradients. In the multivariate regression analysis, PVP and RAP immediately after TIPS were predictors for PSG at short-term control with moderately predictive capacity (AUC = 0.75). Conclusion: Besides the reduction of portal vein pressure, the highly variable right atrial pressure was the main contributor to different pressure gradients. Thus, immediate post-TIPS measurements do not reliably predict portal hemodynamics during follow-up. These findings need to be further investigated with respect to the corresponding clinical course of the patients.
AB - Purpose: Porto-systemic pressure gradient is used to prognosticate rebleeding and resolution of ascites after TIPS. This study investigates the reliability of portal pressure characteristics as quantified immediately after TIPS placement and at short-term control. Patients and Methods: Portal venous pressure (PVP) and right atrial pressure (RAP) were prospectively obtained before and after TIPS as well as ≥ 48 h after TIPS procedure. Porto-systemic pressure gradients (PSG) and pressure changes were calculated. A multivariate regression analysis was performed to predict portal hemodynamics at short-term control. Results: The study included 124 consecutive patients. Indications for TIPS were refractory ascites, variceal bleeding or combinations of both. Pre- and post-interventional PSG yielded 16.4 ± 5.3 mmHg and 5.9 ± 2.7 mmHg, respectively. At that time, 105/124 patients (84.7%) met the target (PSG ≤ 8 mmHg). After 4 days (median), PSG was 8.5 ± 3.5 mmHg and only 66 patients (53%) met that target. In patients exceeding the target PSG at follow-up, PVP was significantly higher and RAP was lower resulting in the increased PSG. The highly variable changes of RAP were the main contributor to different pressure gradients. In the multivariate regression analysis, PVP and RAP immediately after TIPS were predictors for PSG at short-term control with moderately predictive capacity (AUC = 0.75). Conclusion: Besides the reduction of portal vein pressure, the highly variable right atrial pressure was the main contributor to different pressure gradients. Thus, immediate post-TIPS measurements do not reliably predict portal hemodynamics during follow-up. These findings need to be further investigated with respect to the corresponding clinical course of the patients.
UR - http://www.scopus.com/inward/record.url?scp=85120380938&partnerID=8YFLogxK
U2 - 10.1007/s00270-021-03003-z
DO - 10.1007/s00270-021-03003-z
M3 - Journal articles
C2 - 34853873
AN - SCOPUS:85120380938
SN - 0174-1551
VL - 45
SP - 102
EP - 111
JO - CardioVascular and Interventional Radiology
JF - CardioVascular and Interventional Radiology
IS - 1
ER -