TY - JOUR
T1 - Ray-casting based evaluation framework for haptic force feedback during percutaneous transhepatic catheter drainage punctures
AU - Mastmeyer, Andre
AU - Hecht, Tobias
AU - Fortmeier, Dirk
AU - Handels, Heinz
PY - 2014/1/1
Y1 - 2014/1/1
N2 - Purpose: Development of new needle insertion force feedback algorithms requires comparison with a gold standard method. A new evaluation framework was formulated and tested on needle punctures for percutaneous transhepatic catheter drainage (PTCD). Methods: Needle insertion is an established procedure for minimally invasive interventions in the liver. Up-to-date, needle insertions are precisely planned using 2D axial CT slices from 3D data sets. To provide a 3D virtual reality and haptic training and planning environment, the full segmentation of patient data is often a mandatory step. To lessen the time required for manual segmentation, we propose direct haptic volume-rendering based on CT gray values and partially segmented patient data. The core contribution is a new force output evaluation method driven by a ray-casting technique that defines paths from the skin to target structures, i.e., the right hepatic duct near the juncture with the common hepatic duct. A ray-casting method computes insertion trajectories from the skin to the duct considering no-go structures and plausibility criteria. A rating system scores each trajectory. Finally, the best insertion trajectories are selected that reach the target. Along the selected paths, force output comparison between a reference system and the new haptic force output algorithm is carried out, quantified and visualized. Results: The evaluation framework is presented along with an exemplary study of the liver using the atlas data set from a reference patient. In a comparison of our reference method to a newer algorithm, force outputs are found to be similar in 99 % of the paths. Conclusion: The proposed evaluation framework allows reliable detection of problematic PTCD trajectories and provides valuable hints to improve force feedback algorithm development.
AB - Purpose: Development of new needle insertion force feedback algorithms requires comparison with a gold standard method. A new evaluation framework was formulated and tested on needle punctures for percutaneous transhepatic catheter drainage (PTCD). Methods: Needle insertion is an established procedure for minimally invasive interventions in the liver. Up-to-date, needle insertions are precisely planned using 2D axial CT slices from 3D data sets. To provide a 3D virtual reality and haptic training and planning environment, the full segmentation of patient data is often a mandatory step. To lessen the time required for manual segmentation, we propose direct haptic volume-rendering based on CT gray values and partially segmented patient data. The core contribution is a new force output evaluation method driven by a ray-casting technique that defines paths from the skin to target structures, i.e., the right hepatic duct near the juncture with the common hepatic duct. A ray-casting method computes insertion trajectories from the skin to the duct considering no-go structures and plausibility criteria. A rating system scores each trajectory. Finally, the best insertion trajectories are selected that reach the target. Along the selected paths, force output comparison between a reference system and the new haptic force output algorithm is carried out, quantified and visualized. Results: The evaluation framework is presented along with an exemplary study of the liver using the atlas data set from a reference patient. In a comparison of our reference method to a newer algorithm, force outputs are found to be similar in 99 % of the paths. Conclusion: The proposed evaluation framework allows reliable detection of problematic PTCD trajectories and provides valuable hints to improve force feedback algorithm development.
UR - http://www.scopus.com/inward/record.url?scp=84902374339&partnerID=8YFLogxK
U2 - 10.1007/s11548-013-0959-7
DO - 10.1007/s11548-013-0959-7
M3 - Journal articles
C2 - 24281759
AN - SCOPUS:84902374339
SN - 1861-6410
VL - 9
SP - 421
EP - 431
JO - International Journal of Computer Assisted Radiology and Surgery
JF - International Journal of Computer Assisted Radiology and Surgery
IS - 3
ER -