Qualitative Assessment of Titanium versus Carbon Fiber/Polyetheretherketone Pedicle Screw–Related Artifacts: A Cadaveric Study

Darius Kalasauskas*, Lucas Serrano, Moritz Selbach, Marcus Stockinger, Naureen Keric, Marc A. Brockmann, Florian Ringel

*Corresponding author for this work

Abstract

Background: Dorsal instrumentation and decompression are the mainstays of spinal tumor treatment. Replacing titanium screws with carbon fiber–reinforced polyetheretherketone (CFRP) screws can reduce imaging artifacts on neural structures and perturbations of radiation dose. Further reduction of metal content in such screws might enhance the benefit. The aim of this study was to assess the artifacts produced by all-titanium screws (Ti-Ti), CFRP thread–titanium screw heads (C-Ti), and all-CFRP screws (C-C). Methods: A cadaveric spine was used to place Ti-Ti, C-Ti, and C-C consecutively from T2 to S1. Computed tomography and 1.5T and 3T magnetic resonance imaging were performed for each screw system. Axial T1- and T2-weighted sequences of representative thoracic and lumbar regions were assessed for artifacts. The artifacts were classified as not relevant, considerable, or severe. Results: We evaluated 92 screws and made 178 artifact assessments. The artifacts were clearly visible in computed tomography scans but did not influence the visualization of intraspinal structures. Severe magnetic resonance imaging artifacts were found in 28% (17/60, mostly in the thoracic spine) of Ti-Ti, 2% (1/60, all T1 sequences) of C-Ti, and 0% of C-C, and considerable artifacts were found in 47% (28/60) of Ti-Ti, 10% (6/60, only 1 T2 sequence) of C-Ti, and 0% of C-C screws (P < 0.001). Conclusions: CFRP pedicle screws reduced the artifact intensity in spinal structures compared with titanium screws, and may be beneficial for planning radiotherapy and for follow-up imaging. C-C demonstrated an enhanced effect on dorsal structures.

Original languageEnglish
JournalWorld Neurosurgery
Volume166
Pages (from-to)e155-e162
ISSN1878-8750
DOIs
Publication statusPublished - 10.2022

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

DFG Research Classification Scheme

  • 2.23-07 Clinical Neurology, Neurosurgery and Neuroradiology

Fingerprint

Dive into the research topics of 'Qualitative Assessment of Titanium versus Carbon Fiber/Polyetheretherketone Pedicle Screw–Related Artifacts: A Cadaveric Study'. Together they form a unique fingerprint.

Cite this