TY - JOUR
T1 - Nonfluoroscopic catheter ablation of paroxysmal atrial fibrillation
AU - Lyan, Evgeny
AU - Tsyganov, Alexey
AU - Abdrahmanov, Ayan
AU - Morozov, Alexander
AU - Bakytzhanuly, Abay
AU - Tursunbekov, Azat
AU - Nuralinov, Omirbek
AU - Mironovich, Sergey
AU - Klukvin, Alexander
AU - Marinin, Valery
AU - Tilz, Roland Richard
AU - Sawan, Noureddin
N1 - Publisher Copyright:
© 2018 Wiley Periodicals, Inc.
PY - 2018/6
Y1 - 2018/6
N2 - Aims: Radiofrequency catheter ablation of atrial fibrillation (AF) is one of the most complex ablation procedures. Both patients and operators are exposed to scattered radiation. This study evaluated the safety and efficacy of intracardiac echo (ICE)-guided pulmonary vein isolation (PVI) without fluoroscopy. Methods: We retrospectively analyzed the data of 481 consecutive patients with paroxysmal AF undergoing radiofrequency PVI with the CARTO 3 system (Biosense Webster, Diamond Bar, CA, USA). ICE-guided PVI without fluoroscopy and without CT/MRI integration (Nonfluoro group) was performed for 245 patients, and conventional fluoroscopy-guided PVI (Fluoro group) was performed for 236 patients. The primary safety endpoint was the incidence of major adverse events. The primary efficacy endpoint was freedom from AF during follow-up. Secondary endpoints included procedure duration, fluoroscopy duration, and acute PVI rate. Results: Mean procedure times between groups were similar (108.8 ± 18.2 minutes in the Non-fluoro group vs 113.6 ± 26.8 minutes in the Fluoro group; P = not significant [NS]). Acute PVI was achieved in all patients, with mean radiofrequency application times of 43.4 ± 7.5 and 44.4 ± 10.7 minutes for the Nonfluoro and Fluoro groups, respectively (P = NS). The incidence of cardiac tamponade was 1.2% (3/245 patients) in the Nonfluoro group and 0.8% (2/236 patients) in the Fluoro group (P = NS). During 15.2 ± 4.1 months of follow-up, after a single procedure, AF recurrence was documented in 65 of 245 (26.5%) patients and 61 of 236 (25.8%) patients in the Nonfluoro and Fluoro groups, respectively (P = NS). Conclusions: Nonfluoroscopic ICE-guided catheter ablation of AF without prior cardiac image integration or angiography is feasible and safe. PVI without fluoroscopy did not affect procedure duration or long-term efficacy.
AB - Aims: Radiofrequency catheter ablation of atrial fibrillation (AF) is one of the most complex ablation procedures. Both patients and operators are exposed to scattered radiation. This study evaluated the safety and efficacy of intracardiac echo (ICE)-guided pulmonary vein isolation (PVI) without fluoroscopy. Methods: We retrospectively analyzed the data of 481 consecutive patients with paroxysmal AF undergoing radiofrequency PVI with the CARTO 3 system (Biosense Webster, Diamond Bar, CA, USA). ICE-guided PVI without fluoroscopy and without CT/MRI integration (Nonfluoro group) was performed for 245 patients, and conventional fluoroscopy-guided PVI (Fluoro group) was performed for 236 patients. The primary safety endpoint was the incidence of major adverse events. The primary efficacy endpoint was freedom from AF during follow-up. Secondary endpoints included procedure duration, fluoroscopy duration, and acute PVI rate. Results: Mean procedure times between groups were similar (108.8 ± 18.2 minutes in the Non-fluoro group vs 113.6 ± 26.8 minutes in the Fluoro group; P = not significant [NS]). Acute PVI was achieved in all patients, with mean radiofrequency application times of 43.4 ± 7.5 and 44.4 ± 10.7 minutes for the Nonfluoro and Fluoro groups, respectively (P = NS). The incidence of cardiac tamponade was 1.2% (3/245 patients) in the Nonfluoro group and 0.8% (2/236 patients) in the Fluoro group (P = NS). During 15.2 ± 4.1 months of follow-up, after a single procedure, AF recurrence was documented in 65 of 245 (26.5%) patients and 61 of 236 (25.8%) patients in the Nonfluoro and Fluoro groups, respectively (P = NS). Conclusions: Nonfluoroscopic ICE-guided catheter ablation of AF without prior cardiac image integration or angiography is feasible and safe. PVI without fluoroscopy did not affect procedure duration or long-term efficacy.
UR - http://www.scopus.com/inward/record.url?scp=85046151653&partnerID=8YFLogxK
U2 - 10.1111/pace.13321
DO - 10.1111/pace.13321
M3 - Journal articles
C2 - 29566268
AN - SCOPUS:85046151653
SN - 0147-8389
VL - 41
SP - 611
EP - 619
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
IS - 6
ER -