N2 - OBJECTIVES:: Our study aimed to evaluate a three-dimensional (3D) threshold-based, region-growing segmentation algorithm for the assessment of left ventricular (LV) volumes in cardiac MRI. MATERIALS AND METHODS:: Two-dimensional cine steady-state free precession short-axis scans (TR 3 milliseconds, TE 1.5 milliseconds, FA 60°, section thickness 8 mm) covering the entire LV without slice gap were acquired in 44 consecutive patients on a 1.5 Tesla MR system (Magnetom Avanto, Siemens, Germany). LV volumes were assessed with an in-house written 3D threshold-based, interslice region-growing segmentation algorithm, and were compared with manual tracing and short-axis planimetry with semiautomatic contour detection (Argus™ software, Siemens, Germany). RESULTS:: Three-dimensional threshold-based segmentation was feasible in 41 of 44 patients. Results of threshold-based segmentation were not statistically significantly different to manual tracing for the assessment of end-diastolic (EDV: 104.5 ± 32.3 mL vs. 104.7 ± 33.26 mL, P > 0.05), end-systolic (ESV: 34.5 ± 17.2 mL vs. 33.8 ± 17.45 mL, P > 0.05), and stroke (SV: 69.9 ± 25.0 mL vs. 70.9 ± 25.0 mL, P > 0.05) volumes. Bland-Altmann plots showed systematic lower EDV (-12.0 ± 6.7 mL), ESV (-4.8 ± 3.7 mL), and SV (-7.3 ± 7.6 mL), and a systematic higher ejection fraction (0.4% ± 5.0%) for threshold-based segmentation compared with short-axis planimetry with semiautomatic contour detection. Threshold-based segmentation showed an excellent reproducibility with low absolute differences between 2 consecutive analyses (EDV: 0.2 ± 2.2 mL; ESV: 0.5 ± 1.9 mL; SV: 0.6 ± 3.4 mL; EF: 0.5% ± 2.1%). Evaluation times were significantly shorter for threshold-based segmentation (60 ± 16 vs. 278 ± 31 seconds/669 ± 157 seconds, P < 0.0001). CONCLUSION:: Automated threshold-based segmentation of the left ventricle allows fast and reproducible assessment of LV volumes in cardiac MRI. Exclusion of papillary muscles and myocardial trabeculations from LV volumes leads to systematically lower LV volumes compared with short axis planimetry with semi-automatic contour detection.
AB - OBJECTIVES:: Our study aimed to evaluate a three-dimensional (3D) threshold-based, region-growing segmentation algorithm for the assessment of left ventricular (LV) volumes in cardiac MRI. MATERIALS AND METHODS:: Two-dimensional cine steady-state free precession short-axis scans (TR 3 milliseconds, TE 1.5 milliseconds, FA 60°, section thickness 8 mm) covering the entire LV without slice gap were acquired in 44 consecutive patients on a 1.5 Tesla MR system (Magnetom Avanto, Siemens, Germany). LV volumes were assessed with an in-house written 3D threshold-based, interslice region-growing segmentation algorithm, and were compared with manual tracing and short-axis planimetry with semiautomatic contour detection (Argus™ software, Siemens, Germany). RESULTS:: Three-dimensional threshold-based segmentation was feasible in 41 of 44 patients. Results of threshold-based segmentation were not statistically significantly different to manual tracing for the assessment of end-diastolic (EDV: 104.5 ± 32.3 mL vs. 104.7 ± 33.26 mL, P > 0.05), end-systolic (ESV: 34.5 ± 17.2 mL vs. 33.8 ± 17.45 mL, P > 0.05), and stroke (SV: 69.9 ± 25.0 mL vs. 70.9 ± 25.0 mL, P > 0.05) volumes. Bland-Altmann plots showed systematic lower EDV (-12.0 ± 6.7 mL), ESV (-4.8 ± 3.7 mL), and SV (-7.3 ± 7.6 mL), and a systematic higher ejection fraction (0.4% ± 5.0%) for threshold-based segmentation compared with short-axis planimetry with semiautomatic contour detection. Threshold-based segmentation showed an excellent reproducibility with low absolute differences between 2 consecutive analyses (EDV: 0.2 ± 2.2 mL; ESV: 0.5 ± 1.9 mL; SV: 0.6 ± 3.4 mL; EF: 0.5% ± 2.1%). Evaluation times were significantly shorter for threshold-based segmentation (60 ± 16 vs. 278 ± 31 seconds/669 ± 157 seconds, P < 0.0001). CONCLUSION:: Automated threshold-based segmentation of the left ventricle allows fast and reproducible assessment of LV volumes in cardiac MRI. Exclusion of papillary muscles and myocardial trabeculations from LV volumes leads to systematically lower LV volumes compared with short axis planimetry with semi-automatic contour detection.
UR - http://www.scopus.com/inward/record.url?scp=70349694113&partnerID=8YFLogxK
U2 - 10.1097/RLI.0b013e3181a9aaaf
DO - 10.1097/RLI.0b013e3181a9aaaf
M3 - Journal articles
C2 - 19724238
AN - SCOPUS:70349694113
SN - 0020-9996
VL - 44
SP - 635
EP - 640
JO - Investigative Radiology
JF - Investigative Radiology
IS - 10
ER -