TY - JOUR
T1 - Moving table magnetic particle imaging: A stepwise approach preserving high spatio-temporal resolution
AU - Szwargulski, Patryk
AU - Gdaniec, Nadine
AU - Graeser, Matthias
AU - Mäddel, Martin
AU - Griese, Florian
AU - Krishnan, Kannan M.
AU - Buzug, Thorsten M.
AU - Knoppa, Tobias
N1 - Funding Information:
P. S., N. G., M. G., M. M., F. G., and T. K. thankfully acknowledge financial support by the German Research Foundation (DFG, Grant No. KN 1108/2-1) and the Federal Ministry of Education and Research (BMBF, Grant No. 05M16GKA). T. M. B. thankfully acknowledges financial support by the German Research Foundation (DFG, Grant No. BU 1436/9-1). We thank P. Ludewig for animal handling during the animal experiments. We also thank the anonymous reviewers for their very helpful comments that helped us to improve the manuscript.
Publisher Copyright:
© 2018 Society of Photo-Optical Instrumentation Engineers (SPIE).
Copyright:
Copyright 2019 Elsevier B.V., All rights reserved.
PY - 2018/10/1
Y1 - 2018/10/1
N2 - Magnetic particle imaging (MPI) is a highly sensitive imaging method that enables the visualization of magnetic tracer materials with a temporal resolution of more than 46 volumes per second. In MPI, the size of the field of view (FoV) scales with the strengths of the applied magnetic fields. In clinical applications, those strengths are limited by peripheral nerve stimulation, specific absorption rates, and the requirement to acquire images of high spatial resolution. Therefore, the size of the FoV is usually a few cubic centimeters. To bypass this limitation, additional focus fields and/or external object movements can be applied. The latter approach is investigated. An object is moved through the scanner bore one step at a time, whereas the MPI scanner continuously acquires data from its static FoV. Using a 3-D phantom and dynamic 3-D in vivo data, it is shown that the data from such a moving table experiment can be jointly reconstructed after reordering the data with respect to the stepwise object shifts and heart beat phases.
AB - Magnetic particle imaging (MPI) is a highly sensitive imaging method that enables the visualization of magnetic tracer materials with a temporal resolution of more than 46 volumes per second. In MPI, the size of the field of view (FoV) scales with the strengths of the applied magnetic fields. In clinical applications, those strengths are limited by peripheral nerve stimulation, specific absorption rates, and the requirement to acquire images of high spatial resolution. Therefore, the size of the FoV is usually a few cubic centimeters. To bypass this limitation, additional focus fields and/or external object movements can be applied. The latter approach is investigated. An object is moved through the scanner bore one step at a time, whereas the MPI scanner continuously acquires data from its static FoV. Using a 3-D phantom and dynamic 3-D in vivo data, it is shown that the data from such a moving table experiment can be jointly reconstructed after reordering the data with respect to the stepwise object shifts and heart beat phases.
UR - http://www.scopus.com/inward/record.url?scp=85057834732&partnerID=8YFLogxK
U2 - 10.1117/1.JMI.5.4.046002
DO - 10.1117/1.JMI.5.4.046002
M3 - Journal articles
AN - SCOPUS:85057834732
SN - 2329-4302
VL - 5
JO - Journal of Medical Imaging
JF - Journal of Medical Imaging
IS - 4
M1 - 046002
ER -