T1 - Megahertz ultra-wide-field swept-source retina optical coherence tomography compared to current existing imaging devices
AU - Reznicek, Lukas
AU - Klein, Thomas
AU - Wieser, Wolfgang
AU - Kernt, Marcus
AU - Wolf, Armin
AU - Haritoglou, Christos
AU - Kampik, Anselm
AU - Huber, Robert
AU - Neubauer, Aljoscha S.
PY - 2014/1/1
Y1 - 2014/1/1
N2 - Background: To investigate the image quality of wide-angle cross-sectional and reconstructed fundus images based on ultra-megahertz swept-source Fourier domain mode locking (FDML) OCT compared to current generation diagnostic devices. Methods: A 1,050 nm swept-source FDML OCT system was constructed running at 1.68 MHz A-scan rate covering approximately 70° field of view. Twelve normal eyes were imaged with the device applying an isotropically dense sampling protocol (1,900x1,900 A-scans) with a fill factor of 100 %. Obtained OCT scan image quality was compared with two commercial OCT systems (Heidelberg Spectralis and Stratus OCT) of the same 12 eyes. Reconstructed en-face fundus images from the same FDML-OCT data set were compared to color fundus, infrared and ultra-wide-field scanning laser images (SLO). Results: Comparison of cross-sectional scans showed a high overall image quality of the 15x averaged FDML images at 1.68 MHz [overall quality grading score: 8.42±0.52, range 0 (bad)-10 (excellent)] comparable to current spectral-domain OCTs (overall quality grading score: 8.83±0.39, p=0.731). On FDML OCT, a dense 3D data set was obtained covering also the central and mid-peripheral retina. The reconstructed FDML OCT en-face fundus images had high image quality comparable to scanning laser ophthalmoscope (SLO) as judged from retinal structures such as vessels and optic disc. Overall grading score was 8.36±0.51 for FDML OCT vs 8.27±0.65 for SLO (p=0.717). Conclusions: Ultra-wide-field megahertz 3D FDML OCT at 1.68 MHz is feasible, and provides cross-sectional image quality comparable to current spectral-domain OCT devices. In addition, reconstructed en-face visualization of fundus images result in a wide-field view with high image quality as compared to currently available fundus imaging devices. The improvement of >30x in imaging speed over commercial spectral-domain OCT technology enables high-density scan protocols leading to a data set for high quality cross-sectional and en-face images of the posterior segment.
AB - Background: To investigate the image quality of wide-angle cross-sectional and reconstructed fundus images based on ultra-megahertz swept-source Fourier domain mode locking (FDML) OCT compared to current generation diagnostic devices. Methods: A 1,050 nm swept-source FDML OCT system was constructed running at 1.68 MHz A-scan rate covering approximately 70° field of view. Twelve normal eyes were imaged with the device applying an isotropically dense sampling protocol (1,900x1,900 A-scans) with a fill factor of 100 %. Obtained OCT scan image quality was compared with two commercial OCT systems (Heidelberg Spectralis and Stratus OCT) of the same 12 eyes. Reconstructed en-face fundus images from the same FDML-OCT data set were compared to color fundus, infrared and ultra-wide-field scanning laser images (SLO). Results: Comparison of cross-sectional scans showed a high overall image quality of the 15x averaged FDML images at 1.68 MHz [overall quality grading score: 8.42±0.52, range 0 (bad)-10 (excellent)] comparable to current spectral-domain OCTs (overall quality grading score: 8.83±0.39, p=0.731). On FDML OCT, a dense 3D data set was obtained covering also the central and mid-peripheral retina. The reconstructed FDML OCT en-face fundus images had high image quality comparable to scanning laser ophthalmoscope (SLO) as judged from retinal structures such as vessels and optic disc. Overall grading score was 8.36±0.51 for FDML OCT vs 8.27±0.65 for SLO (p=0.717). Conclusions: Ultra-wide-field megahertz 3D FDML OCT at 1.68 MHz is feasible, and provides cross-sectional image quality comparable to current spectral-domain OCT devices. In addition, reconstructed en-face visualization of fundus images result in a wide-field view with high image quality as compared to currently available fundus imaging devices. The improvement of >30x in imaging speed over commercial spectral-domain OCT technology enables high-density scan protocols leading to a data set for high quality cross-sectional and en-face images of the posterior segment.
UR - http://www.scopus.com/inward/record.url?scp=84902248268&partnerID=8YFLogxK
U2 - 10.1007/s00417-014-2640-4
DO - 10.1007/s00417-014-2640-4
M3 - Journal articles
C2 - 24789467
AN - SCOPUS:84902248268
SN - 0721-832X
VL - 252
SP - 1009
EP - 1016
JO - Graefe's Archive for Clinical and Experimental Ophthalmology
JF - Graefe's Archive for Clinical and Experimental Ophthalmology
IS - 6
ER -