Abstract
Initial measurements of water vapor temperature using a Fourier domain mode locking (FDML) laser were performed in a carefully controlled homogenous charge compression ignition engine with optical access. The gas temperature was inferred from water absorption spectra that were measured each 0.25 crank angle degrees (CAD) over a range of 150 CAD. Accuracy was tested in a well controlled shock tube experiment. This paper will validate the potential of this FDML laser in combustion applications.
| Original language | English |
|---|---|
| Title of host publication | SAE 2006 World Congress & Exhibition |
| Publisher | SAE International |
| Publication date | 01.04.2006 |
| DOIs | |
| Publication status | Published - 01.04.2006 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 9 Industry, Innovation, and Infrastructure
Fingerprint
Dive into the research topics of 'Measurements of Gas Temperature in a HCCI Engine Using a Fourier Domain Mode Locking Laser'. Together they form a unique fingerprint.Cite this