Initial Experience with the E-liac® Iliac Branch Device for the Endovascular Aortic Repair of Aorto-iliac Aneurysm

Susanne Anton*, Marcus Wiedner, Erik Stahlberg, Fabian Jacob, Jörg Barkhausen, Jan Peter Goltz

*Corresponding author for this work
3 Citations (Scopus)

Abstract

Purpose: Occlusion of internal iliac arteries during endovascular treatment (EVAR) of abdominal aortic (AAA) and common iliac artery aneurysms might be associated with ischemic pelvic complications. This study evaluates technical and clinical success, safety and mid-term results of a novel iliac branch device (IBD) for revascularization of the internal iliac artery (IIA) during EVAR. Materials and Methods: Retrospectively, we identified 21 men (mean age 73.3 ± 6.2 years) treated for aorto-iliac aneurysms by use of a novel IBD (E-liac®, Jotec Hechingen, Germany). We analyzed safety (30-day survival), technical (no type I and III endoleaks, “EL”), clinical (no ischemic complications) success, mid-term patency of this IBD, peri-procedural complications, occurrence of type II ELs, rate of re-interventions and additional treatment of the revascularized IIA for landing zone preparation. Results: Twenty-three IBDs were implanted. Aneurysms of the ipsilateral IIA were present in 6/23 IIAs (26.1%). Super-selective branch embolization was performed in these patients and the landing zone for the iliac sidebranch stent-graft was within the superior gluteal artery. Mean follow-up was 341 days (range 4–1103 days). Technical success and 30-day survival were 100%. Clinical success was 95.2%. Primary patency of the IBDs was 100% at 12 months. Peri-procedural complications occurred in 3/21 patients (14.3%), none of them related to the IBD. AAA-related type II ELs were found in 6 patients (28.6%), IBD-related ELs in 4/23 IBDs (17.4%) (two type Ib, two type II endoleaks). Overall re-intervention rate was 23.8%, IBD-related 8.7%. Conclusion: Utilization of the E-liac® IBD is safe and effective for the treatment of aorto-iliac aneurysms.

Original languageEnglish
JournalCardioVascular and Interventional Radiology
Volume41
Issue number5
Pages (from-to)683-691
Number of pages9
ISSN0174-1551
DOIs
Publication statusPublished - 01.05.2018

Research Areas and Centers

  • Academic Focus: Biomedical Engineering

DFG Research Classification Scheme

  • 205-30 Radiology, Nuclear Medicine, Radiation Therapy and Radiobiology
  • 205-32 Medical Physics, Biomedical Engineering

Fingerprint

Dive into the research topics of 'Initial Experience with the E-liac® Iliac Branch Device for the Endovascular Aortic Repair of Aorto-iliac Aneurysm'. Together they form a unique fingerprint.

Cite this