Abstract
Objective Evaluation of the impact of the sheath diameter on vascular complications and mortality in transfemoral aortic valve implantation. Method Between 2012 and 2014, 183 patients underwent the procedure using a sheath diameter of 18–24 F. This collective was divided into two groups: group 1, with a sheath diameter of 18F (G1, n = 94), consisted of patients with 18F Medtronic Sentrant and 18 F Direct Flow sheaths, and group 2 with a sheath diameter of 19–24 F (G2, n = 89) consisted of patients with Edwards expandable e-sheath and Solopath sheaths. Perclose-Proglide® was used as a closure device in all patients. Results G1 had significantly more female patients (64.9% vs. 46.1% in G2, p = 0.01) and the average BMI was lower (26 ± 4.5% vs. 27.4 ± 4.7%, p = 0.03). There was no significant difference in the incidence of major and minor vascular complications (G1: 12.8% vs. G2: 12.4%, p = 0.9). 30-day mortality was similar in both groups (G1: 6.4 ± 2.5% [95% CI: 0.88–0.98], G2: 3.7 ± 1.9% [95% CI: 0.92–0.99]. The Kaplan Meier analysis of survival revealed no significant differences either. Conclusion The difference in sheath diameter had no effect on either incidence or severity of vascular complications. There was no impact on mortality either.
| Original language | English |
|---|---|
| Article number | e0183658 |
| Journal | PLoS ONE |
| Volume | 12 |
| Issue number | 8 |
| DOIs | |
| Publication status | Published - 08.2017 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Fingerprint
Dive into the research topics of 'Impact of sheath diameter of different sheath types on vascular complications and mortality in transfemoral TAVI approaches using the Proglide closure device'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver