TY - JOUR
T1 - Hypoglossal nerve stimulation for obstructive sleep apnea: updated position paper of the German Society of Oto-Rhino-Laryngology, Head and Neck Surgery
AU - Steffen, Armin
AU - Heiser, Clemens
AU - Galetke, Wolfgang
AU - Herkenrath, Simon Dominik
AU - Maurer, Joachim T.
AU - Günther, Eck
AU - Stuck, Boris A.
AU - Woehrle, Holger
AU - Löhler, Jan
AU - Randerath, Winfried
N1 - Publisher Copyright:
© 2021, The Author(s).
PY - 2021
Y1 - 2021
N2 - Since the first statement of the German Society of Oto-Rhino-Laryngology, hypoglossal nerve stimulation (HNS) is meanwhile an established treatment option for obstructive sleep apnea (OSA). There are three HNS systems available in Germany which differ in their technical details of the underlying comparable basic principle. For the unilateral HNS with respiratory sensing, several comparative studies, high-volume register analysis and long-term reports exist. The continuous HNS without respiratory sensing does not require a sleep endoscopy for indication. For the bilateral continuous HNS as the single partially implantable device, a feasibility study exists. For indication, the assessment of positive airway pressure failure by sleep medicine is crucial, and the decision for HNS should be made in discussion of other treatment options for at least moderate OSA. The implantation center holds primarily responsibility among the interdisciplinary sleep team and is primary contact for the patient in problems. This depicts why structural processes are required to secure outcome quality and minimize the complications. The aftercare of HNS patients can be provided interdisciplinary and by different medical institutions, whereat, minimal reporting standards to document outcome and usage are recommended.
AB - Since the first statement of the German Society of Oto-Rhino-Laryngology, hypoglossal nerve stimulation (HNS) is meanwhile an established treatment option for obstructive sleep apnea (OSA). There are three HNS systems available in Germany which differ in their technical details of the underlying comparable basic principle. For the unilateral HNS with respiratory sensing, several comparative studies, high-volume register analysis and long-term reports exist. The continuous HNS without respiratory sensing does not require a sleep endoscopy for indication. For the bilateral continuous HNS as the single partially implantable device, a feasibility study exists. For indication, the assessment of positive airway pressure failure by sleep medicine is crucial, and the decision for HNS should be made in discussion of other treatment options for at least moderate OSA. The implantation center holds primarily responsibility among the interdisciplinary sleep team and is primary contact for the patient in problems. This depicts why structural processes are required to secure outcome quality and minimize the complications. The aftercare of HNS patients can be provided interdisciplinary and by different medical institutions, whereat, minimal reporting standards to document outcome and usage are recommended.
UR - http://www.scopus.com/inward/record.url?scp=85108260425&partnerID=8YFLogxK
U2 - 10.1007/s00405-021-06902-6
DO - 10.1007/s00405-021-06902-6
M3 - Scientific review articles
AN - SCOPUS:85108260425
SN - 0937-4477
JO - European Archives of Oto-Rhino-Laryngology
JF - European Archives of Oto-Rhino-Laryngology
ER -