High-precision radiotherapy of motor deficits due to metastatic spinal cord compression (PRE-MODE): A multicenter phase 2 study

Dirk Rades*, Jon Cacicedo, Antonio J. Conde-Moreno, Claudia Doemer, Jürgen Dunst, Darejan Lomidze, Barbara Segedin, Denise Olbrich, Niels Henrik Holländer

*Corresponding author for this work

Abstract

Background: For metastatic spinal cord compression (MSCC), conventional radiotherapy with 10 × 3 Gy in 2 weeks results in better local progression-free survival (LPFS) than 5 × 4 Gy in 1 week. Since patients with MSCC are often significantly impaired, an overall treatment time of 1 week would be preferable if resulting in similar outcomes as longer programs. This may be achieved with 5 × 5 Gy in 1 week, since the biologically effective dose is similar to 10 × 3 Gy. It can be expected that 5 × 5 Gy (like 10 × 3) Gy results in better LPFS than 5 × 4 Gy in 1 week. Methods/Design: This phase 2 study investigates LPFS after high-precision RT with 5 × 5 Gy in 1 week. LPFS is defined as freedom from both progression of motor deficits during RT and new or progressive motor deficits dur to an in-field recurrence of MSCC following RT. Considering the tolerance dose of the spinal cord, 5 × 5 Gy can be safely administered with high-precision radiotherapy such as volumetric modulated arc therapy (VMAT) or stereotactic body radiotherapy (SBRT). Maximum dose to the spinal cord should not exceed 101.5% of the prescribed dose to keep the risk of radiation myelopathy below 0.03%. Primary endpoint is LPFS at 6 months following radiotherapy; secondary endpoints include motor function/ability to walk, sensory function, sphincter dysfunction, LPFS directly and 1 and 3 months following radiotherapy, overall survival, pain relief, quality of life and toxicity. Follow-up visits will be performed directly and at 1, 3 and 6 months following radiotherapy. After completion of this phase 2 study, patients will be compared to a historical control group receiving conventional radiotherapy with 5 × 4 Gy in 1 week. Forty-four patients will be included assuming 5 × 5 Gy will provide the same benefit in LPFS when compared to 5 × 4 Gy as reported for 10 × 3 Gy. Discussion: If superiority regarding LPFS is shown for high-precision radiotherapy with 5 × 5 Gy when compared to conventional radiotherapy with 5 × 4 Gy, patients with MSCC would benefit from 5 × 5 Gy, since high LPFS rates could be achieved with 1 week of radiotherapy instead of 2 weeks (10 × 3 Gy). Trial registration: clinicaltrials.gov NCT03070431. Registered 27 February 2017.

Original languageEnglish
Article number818
JournalBMC Cancer
Volume17
Issue number1
DOIs
Publication statusPublished - 04.12.2017

Funding

The study is part of the INTERREG-project InnoCan, which is funded by the European Union (reference: Innoc 11-1.0-15). The funding body has no role in the design of the study, in collection, analysis and interpretation of the data and in writing of the manuscript.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'High-precision radiotherapy of motor deficits due to metastatic spinal cord compression (PRE-MODE): A multicenter phase 2 study'. Together they form a unique fingerprint.

Cite this