TY - JOUR
T1 - General Versus Local Anesthesia With Conscious Sedation in Transcatheter Aortic Valve Implantation: The Randomized SOLVE-TAVI Trial
AU - SOLVE-TAVI Investigators
AU - Thiele, Holger
AU - Kurz, Thomas
AU - Feistritzer, Hans Josef
AU - Stachel, Georg
AU - Hartung, Philipp
AU - Lurz, Philipp
AU - Eitel, Ingo
AU - Marquetand, Christoph
AU - Nef, Holger
AU - Doerr, Oliver
AU - Vigelius-Rauch, Ursula
AU - Lauten, Alexander
AU - Landmesser, Ulf
AU - Treskatsch, Sascha
AU - Abdel-Wahab, Mohamed
AU - Sandri, Marcus
AU - Holzhey, David
AU - Borger, Michael
AU - Ender, Jörg
AU - Ince, Hüseyin
AU - Öner, Alper
AU - Meyer-Saraei, Roza
AU - Hambrecht, Rainer
AU - Fach, Andreas
AU - Augenstein, Thomas
AU - Frey, Norbert
AU - König, Inke R.
AU - Vonthein, Reinhard
AU - Rückert, Yvonne
AU - Funkat, Anne Kathrin
AU - Desch, Steffen
AU - Berggreen, Astrid E.
AU - Heringlake, Matthias
AU - de Waha-Thiele, Suzanne
N1 - Publisher Copyright:
© 2020 Lippincott Williams and Wilkins. All rights reserved.
PY - 2020/10/13
Y1 - 2020/10/13
N2 - BACKGROUND: In clinical practice, local anesthesia with conscious sedation (CS) is performed in roughly 50% of patients undergoing transcatheter aortic valve replacement. However, no randomized data assessing the safety and efficacy of CS versus general anesthesia (GA) are available. METHODS: The SOLVE-TAVI (Comparison of Second-Generation Self-Expandable Versus Balloon-Expandable Valves and General Versus Local Anesthesia in Transcatheter Aortic Valve Implantation) trial is a multicenter, open-label, 2×2 factorial, randomized trial of 447 patients with aortic stenosis undergoing transfemoral transcatheter aortic valve replacement comparing CS versus GA. The primary efficacy end point was powered for equivalence (equivalence margin 10% with significance level 0.05) and consisted of the composite of all-cause mortality, stroke, myocardial infarction, infection requiring antibiotic treatment, and acute kidney injury at 30 days. RESULTS: The primary composite end point occurred in 27.2% of CS and 26.4% of GA patients (rate difference, 0.8 [90% CI, -6.2 to 7.8]; Pequivalence=0.015). Event rates for the individual components were as follows: all-cause mortality, 3.2% versus 2.3% (rate difference, 1.0 [90% CI, -2.9 to 4.8]; Pequivalence<0.001); stroke, 2.4% versus 2.8% (rate difference, -0.4 [90% CI, -3.8 to 3.8]; Pequivalence<0.001); myocardial infarction, 0.5% versus 0.0% (rate difference, 0.5 [90% CI, -3.0 to 3.9]; Pequivalence<0.001), infection requiring antibiotics 21.1% versus 22.0% (rate difference, -0.9 [90% CI, -7.5 to 5.7]; Pequivalence=0.011); acute kidney injury, 9.0% versus 9.2% (rate difference, -0.2 [90% CI, -5.2 to 4.8]; Pequivalence=0.0005). There was a lower need for inotropes or vasopressors with CS (62.8%) versus GA (97.3%; rate difference, -34.4 [90% CI, -41.0 to -27.8]). CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral transcatheter aortic valve replacement, use of CS compared with GA resulted in similar outcomes for the primary efficacy end point. These findings suggest that CS can be safely applied for transcatheter aortic valve replacement. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02737150.
AB - BACKGROUND: In clinical practice, local anesthesia with conscious sedation (CS) is performed in roughly 50% of patients undergoing transcatheter aortic valve replacement. However, no randomized data assessing the safety and efficacy of CS versus general anesthesia (GA) are available. METHODS: The SOLVE-TAVI (Comparison of Second-Generation Self-Expandable Versus Balloon-Expandable Valves and General Versus Local Anesthesia in Transcatheter Aortic Valve Implantation) trial is a multicenter, open-label, 2×2 factorial, randomized trial of 447 patients with aortic stenosis undergoing transfemoral transcatheter aortic valve replacement comparing CS versus GA. The primary efficacy end point was powered for equivalence (equivalence margin 10% with significance level 0.05) and consisted of the composite of all-cause mortality, stroke, myocardial infarction, infection requiring antibiotic treatment, and acute kidney injury at 30 days. RESULTS: The primary composite end point occurred in 27.2% of CS and 26.4% of GA patients (rate difference, 0.8 [90% CI, -6.2 to 7.8]; Pequivalence=0.015). Event rates for the individual components were as follows: all-cause mortality, 3.2% versus 2.3% (rate difference, 1.0 [90% CI, -2.9 to 4.8]; Pequivalence<0.001); stroke, 2.4% versus 2.8% (rate difference, -0.4 [90% CI, -3.8 to 3.8]; Pequivalence<0.001); myocardial infarction, 0.5% versus 0.0% (rate difference, 0.5 [90% CI, -3.0 to 3.9]; Pequivalence<0.001), infection requiring antibiotics 21.1% versus 22.0% (rate difference, -0.9 [90% CI, -7.5 to 5.7]; Pequivalence=0.011); acute kidney injury, 9.0% versus 9.2% (rate difference, -0.2 [90% CI, -5.2 to 4.8]; Pequivalence=0.0005). There was a lower need for inotropes or vasopressors with CS (62.8%) versus GA (97.3%; rate difference, -34.4 [90% CI, -41.0 to -27.8]). CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral transcatheter aortic valve replacement, use of CS compared with GA resulted in similar outcomes for the primary efficacy end point. These findings suggest that CS can be safely applied for transcatheter aortic valve replacement. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02737150.
UR - http://www.scopus.com/inward/record.url?scp=85092944995&partnerID=8YFLogxK
U2 - 10.1161/CIRCULATIONAHA.120.046451
DO - 10.1161/CIRCULATIONAHA.120.046451
M3 - Journal articles
C2 - 32819145
AN - SCOPUS:85092944995
SN - 0009-7322
VL - 142
SP - 1437
EP - 1447
JO - Circulation
JF - Circulation
IS - 15
ER -