Focal impulse and rotor modulation using the novel 64-electrode basket catheter: Electrogram characteristics of human rotors

Tina Lin*, Andreas Rillig, Tudor Bucur, Andreas Metzner, Shibu Mathew, Erik Wissner, Peter Wohlmuth, Karl Heinz Kuck, Feifan Ouyang, Roland Richard Tilz

*Corresponding author for this work
17 Citations (Scopus)

Abstract

Aims Ablation of fractionated electrograms (EGMs) has been performed to eliminate areas of slow conduction in atrial fibrillation (AF). The rotor hypothesis suggests that rapidly activating spiral waves perpetuate and maintain AF. This study describes the EGM characteristics of AF rotors, using the novel 64-electrode basket catheter. Methods and results Twenty-five patients (male n = 16) with AF (paroxysmal n = 10) underwent focal impulse and rotor modulation. A 3.5 mm irrigated-tip ablation catheter was placed at the identified rotor core and EGMs were analysed for amplitude, characteristics (single-EGM, fractionated-EGM, and continuous-EGM), and cycle length over 10 s. A total of 72 rotors were identified [right atrium (RA) = 13, left atrium (LA) = 59]. Seven rotors were excluded from EGM analysis due to location in the pulmonary veins. Single-EGMs were more frequent in the RA compared with the LA (8 (61.5) vs. 12 (23.1); P < 0.01) and EGM amplitudes were smaller in LA rotors when compared with RA rotors (0.14 (0.08-0.17) mV vs. 0.19 (0.15-0.29) mV; P = 0.029). In patients with persistent AF, single-EGMs were observed more often in the right-sided rotors compared with left-sided rotors (4 (57.1) vs. 5 (14.3); P = 0.012), and EGM amplitudes were smaller in patients with persistent AF compared with paroxysmal atrial fibrillation (PAF) patients (0.15 (0.09-0.19) mV vs. 0.22 (0.17-0.47) mV; P = 0.03). Furthermore, the prevalence of fractionated- EGMs was higher in patients with persistent AF compared with PAF patients (31/42 (73.8) vs. 9/23 (39.1); P = 0.03). Conclusion There are no characteristic rotor-EGM potentials. Rotor-EGM characteristics are different between the RA and LA. Although rotors are not associated with abnormal EGMs, rotor-EGMs in persistent AF were more fractionated with lower amplitudes compared with that in PAF.

Original languageEnglish
JournalEuropace
Volume17
Issue number12
Pages (from-to)1791-1797
Number of pages7
ISSN1099-5129
DOIs
Publication statusPublished - 10.11.2015

Research Areas and Centers

  • Centers: Cardiological Center Luebeck (UHZL)

DFG Research Classification Scheme

  • 205-12 Cardiology, Angiology

Fingerprint