CT Normalization by Paired Image-to-image Translation for Lung Emphysema Quantification

Insa Lange*, Fabian Jacob, Alex Frydrychowicz, Heinz Handels, Jan Ehrhardt

*Corresponding author for this work

Abstract

In this work a UNet-based normalization method by paired image-to-image translation of Chest CT images was developed. Due to different noise-levels, emphysema quantification shows sincere subordination to the choice of the filterkernel. Images for training and testing of 71 patients were available, reconstructed using the smooth Siemens B20f filterkernel and the sharp B80f _lterkernel. Results were evaluated in regard to the image quality, including a visual assessment by two imaging experts, the L1 distance, the emphysema quantification (emphysema index and Dice overlap of emphysema segmentations). Emphysema quantification was compared to classical normalization methods. Our approach lead to very good image quality in which the mean B20f L1 distance to the B80f could be reduced by about 88:5% and the mean Dice was raised by 189% after normalization. Classical methods were outperformed. Even though small differences between B20f and normalized B80f images were noticed, the normalized images were found to be overall of diagnostic quality.
Original languageEnglish
Title of host publicationBildverarbeitung für die Medizin 2021
EditorsChristoph Palm, Thomas M. Deserno, Heinz Handels, Andreas Maier, Klaus Maier-Hein, Thomas Tolxdorff
Number of pages6
PublisherSpringer Vieweg, Wiesbaden
Publication date27.02.2021
Pages276-281
ISBN (Print)978-3-658-33197-9
ISBN (Electronic)978-3-658-33198-6
DOIs
Publication statusPublished - 27.02.2021
EventBildverarbeitung für die Medizin 2021
-
Duration: 07.03.202109.03.2021

Fingerprint

Dive into the research topics of 'CT Normalization by Paired Image-to-image Translation for Lung Emphysema Quantification'. Together they form a unique fingerprint.

Cite this