Skip to main navigation Skip to search Skip to main content

Comparison of Automated Thresholding Algorithms in Optical Coherence Tomography Angiography Image Analysis

  • David Prangel
  • , Michelle Prasuhn*
  • , Felix Rommel
  • , Salvatore Grisanti
  • , Mahdy Ranjbar
  • *Corresponding author for this work
  • Laboratory for Angiogenesis & Ocular Cell Transplantation

Abstract

(1) Background: Calculation of vessel density in optical coherence tomography angiography (OCTA) images with thresholding algorithms varies in clinical routine. The ability to discriminate healthy from diseased eyes based on perfusion of the posterior pole is critical and may depend on the algorithm applied. This study assessed comparability, reliability, and ability in the discrimination of commonly used automated thresholding algorithms. (2) Methods: Vessel density in full retina and choriocapillaris slabs were calculated with five previously published automated thresholding algorithms (Default, Huang, ISODATA, Mean, and Otsu) for healthy and diseased eyes. The algorithms were investigated with LD-F2-analysis for intra-algorithm reliability, agreement, and the ability to discriminate between physiological and pathological conditions. (3) Results: LD-F2-analyses revealed significant differences in estimated vessel densities for the algorithms (p < 0.001). For full retina and choriocapillaris slabs, intra-algorithm values range from excellent to poor, depending on the applied algorithm; the inter-algorithm agreement was low. Discrimination was good for the full retina slabs, but poor when applied to the choriocapillaris slabs. The Mean algorithm demonstrated an overall good performance. (4) Conclusions: Automated threshold algorithms are not interchangeable. The ability for discrimination depends on the analyzed layer. Concerning the full retina slab, all of the five evaluated automated algorithms had an overall good ability for discrimination. When analyzing the choriocapillaris, it might be useful to consider another algorithm.

Original languageEnglish
Article number1973
JournalJournal of Clinical Medicine
Volume12
Issue number5
ISSN2077-0383
DOIs
Publication statusPublished - 03.2023

Funding

Funders
Land Schleswig-Holstein

    UN SDGs

    This output contributes to the following UN Sustainable Development Goals (SDGs)

    1. SDG 3 - Good Health and Well-being
      SDG 3 Good Health and Well-being

    Research Areas and Centers

    • Academic Focus: Biomedical Engineering

    DFG Research Classification Scheme

    • 2.23-11 Ophthalmology
    • 2.22-32 Medical Physics, Biomedical Technology

    Fingerprint

    Dive into the research topics of 'Comparison of Automated Thresholding Algorithms in Optical Coherence Tomography Angiography Image Analysis'. Together they form a unique fingerprint.

    Cite this