Cobalt serum levels differ in well functioning Birmingham resurfacing and Birmingham modular THA

Lisa Renner, Martin Faschingbauer, Tom Schmidt-Braekling, Friedrich Boettner*

*Corresponding author for this work
3 Citations (Scopus)

Abstract

Introduction: Metal-on-metal (MoM) bearings are known to release metal ions secondary to wear and corrosion. This may cause local reactions (adverse soft tissue reactions and osteolysis) and systemic effects. Little is known about the exact pattern and the differences between large head MoM total hip replacements (THA) and resurfacings (HR). Questions: (1) Is there a difference in metal ion concentrations between HR and MoM-THR using the same bearing design (Birmingham Hip Resurfacing System, Smith & Nephew, Inc. Memphis, TN, USA)? (2) Are metal ion levels changing over time in MoM-THA or HR? (3) Do acetabular inclination angle and femoral component size influence cobalt and chromium levels? Is there a correlation between clinical outcome and metal ion levels? Materials and methods: A retrospective analysis was conducted in 77 well functioning unilateral Birmingham HR and 42 well functioning unilateral modular Birmingham MoM-THA (Smith & Nephew, Inc. Memphis, TN, USA) operated on between 2007 and 2012. Blood samples were taken at a minimum of 13 months and subsequent during annual follow-ups. Results: (1) Cobalt levels were significantly higher in MoM-THA compared to HR (p < 0.001). There was no significant difference in chromium levels (p = 0.313). (2) Cobalt is increasing over time in MoM-THA (p = 0.030) whereas metal ions remain stable in HR. (3) Metal ion levels were not affected by acetabular inclination angle and femoral component size in MoM-THA. Chromium levels correlate with the femoral component size (r = −0.240; p = 0.037), the UCLA activity score (r = −0.344; p = 0.003) and the VAS (r = 0.263; p = 0.38) in HR. Conclusion: Considering that HR and MoM-THA used the same MoM bearing design, increased cobalt levels may be related to trunnion wear or corrosion. Elevated cobalt levels should raise concern for corrosion related failure in MoM-THA.

Original languageEnglish
JournalArchives of Orthopaedic and Trauma Surgery
Volume136
Issue number5
Pages (from-to)715-721
Number of pages7
ISSN0936-8051
DOIs
Publication statusPublished - 01.05.2016
Externally publishedYes

Research Areas and Centers

  • Academic Focus: Center for Brain, Behavior and Metabolism (CBBM)

Fingerprint

Dive into the research topics of 'Cobalt serum levels differ in well functioning Birmingham resurfacing and Birmingham modular THA'. Together they form a unique fingerprint.

Cite this