T1 - Characterisation of MCP-600D and MCP-700D thermoluminescence detectors and their applicability for photoneutron detection
AU - Brunckhorst, E.
AU - Sheng, X.
AU - Todorovic, M.
AU - Becker, J.
AU - Cremers, F.
N1 - Copyright:
Copyright 2009 Elsevier B.V., All rights reserved.
PY - 2008
Y1 - 2008
N2 - This paper presents the characteristics of two high-sensitive LiF:Mg,Cu,P thermoluminescence detectors (TLDs) named MCP-600D and MCP-700D [thermoluminescence detector (TLD) Poland]. Furthermore, the applicability of both detectors used as a paired system for photoneutron detection in a high-energy photon field at a linear accelerator is shown. For MCP-600D and MCP-700D, the batch homogeneity is within 22 and 14%, respectively (2 SD). Correction for the individual response of each TLD leads to a reproducibility of 5 and 4%, respectively Both TLD types reveal a linear detector response to dose up to 4 Gy. The energy dependence for both is within 2% for 4 and 6 MV photons. For a 15 MV photon beam, the MCP-600D shows a higher response (10%); compared with the MCP-700D (2%). The MCP-600D is capable of detecting extra doses due to photoneutrons in a 15 MV photon exposure; however, the signal for an open field of the used linear accelerator is in the order of the reproducibility. Using a kind of albedo technique allows detection of photoneutrons in the open photon field anyhow. The neutron detection limit is 10 μGy neutron dose per 1 Gy photon dose. Reproducibility of the TLDs, however, requires more than 10 detectors to determine results with an uncertainty of <5%.
AB - This paper presents the characteristics of two high-sensitive LiF:Mg,Cu,P thermoluminescence detectors (TLDs) named MCP-600D and MCP-700D [thermoluminescence detector (TLD) Poland]. Furthermore, the applicability of both detectors used as a paired system for photoneutron detection in a high-energy photon field at a linear accelerator is shown. For MCP-600D and MCP-700D, the batch homogeneity is within 22 and 14%, respectively (2 SD). Correction for the individual response of each TLD leads to a reproducibility of 5 and 4%, respectively Both TLD types reveal a linear detector response to dose up to 4 Gy. The energy dependence for both is within 2% for 4 and 6 MV photons. For a 15 MV photon beam, the MCP-600D shows a higher response (10%); compared with the MCP-700D (2%). The MCP-600D is capable of detecting extra doses due to photoneutrons in a 15 MV photon exposure; however, the signal for an open field of the used linear accelerator is in the order of the reproducibility. Using a kind of albedo technique allows detection of photoneutrons in the open photon field anyhow. The neutron detection limit is 10 μGy neutron dose per 1 Gy photon dose. Reproducibility of the TLDs, however, requires more than 10 detectors to determine results with an uncertainty of <5%.
UR - http://www.scopus.com/inward/record.url?scp=57249084156&partnerID=8YFLogxK
U2 - 10.1093/rpd/ncn251
DO - 10.1093/rpd/ncn251
M3 - Journal articles
C2 - 18922825
AN - SCOPUS:57249084156
SN - 0144-8420
VL - 131
SP - 513
EP - 520
JO - Radiation Protection Dosimetry
JF - Radiation Protection Dosimetry
IS - 4
ER -