Abstract
For diagnosing a stenosis or an aneurysm, the shape parameters of the diseased vessel parts are needed by physicians. Therefore, a fully-automatic extraction of this shape from a volume representation has been developed. This paper analyses the blood vessel branch labeling acceleration algorithms and proposes two improved methods. The first one is called the surface wave propagation method which restricts the wave moving along the blood vessel surface. The second one replaces the thinning algorithm with the surface propagation to extract the center lines and the bifurcations of the blood vessels. Experiment results show that two improved methods can decrease the computation time and keep the labeling accuracy.
Original language | English |
---|---|
Title of host publication | Proceedings of 2009 BVM -- Bildverarbeitung für die Medizin |
Number of pages | 5 |
Volume | 574 |
Publisher | CEUR-WS.org |
Publication date | 01.03.2010 |
Pages | 132-136 |
Publication status | Published - 01.03.2010 |
Externally published | Yes |
Event | BVM 2010 - Aachen, Germany Duration: 14.03.2010 → 16.03.2010 Conference number: 102532 http://medinfo.userpage.fu-berlin.de/BVM2010/Seiten/gesellschaftsabend.html |