4D flow CMR analysis comparing patients with anatomically shaped aortic sinus prostheses, tube prostheses and healthy subjects introducing the wall shear stress gradient: A case control study

Malte Maria Sieren*, Victoria Schultz, Buntaro Fujita, Franz Wegner, Markus Huellebrand, Michael Scharfschwerdt, Hans Hinrich Sievers, Joerg Barkhausen, Alex Frydrychowicz, Thekla Helene Oechtering

*Corresponding author for this work

Abstract

Background: Anatomically pre-shaped sinus prostheses (SP) were developed to mimic the aortic sinus with the goal to preserve near physiological hemodynamic conditions after valve-sparing aortic root replacement. Although SP have shown more physiological flow patterns, a comparison to straight tube prosthesis and the analysis of derived quantitative parameters is lacking. Hence, this study sought to analyze differences in aortic wall shear stress (WSS) between anatomically pre-shaped SP, conventional straight tube prostheses (TP), and age-matched healthy subjects) using time-resolved 3-dimensional flow cardiovascular magnetic resonance (4D Flow CMR). Moreover, the WSS gradient was introduced and analyzed regarding its sensitivity to detect changes in hemodynamics and its dependency on the expression of secondary flow patterns. Methods: Twelve patients with SP (12 male, 62 ± 9yr), eight patients with TP (6 male, 59 ± 9yr), and twelve healthy subjects (2 male, 55 ± 6yr) were examined at 3 T with a 4D Flow CMR sequence in this case control study. Six analysis planes were placed in the thoracic aorta at reproducible landmarks. The following WSS parameters were recorded: WSSavg (spatially averaged over the contour at peak systole), max. WSSseg (maximum segmental WSS), min. WSSseg (minimum segmental WSS) and the WSS Gradient, calculated as max. WSSseg - min. WSSseg. Kruskal-Wallis- and Mann-Whitney-U-Test were used for statistical comparison of groups. Occurrence and expression of secondary flow patterns were evaluated and correlated to WSS values using Spearman's correlation coefficient. Results: In the planes bordering the prosthesis all WSS values were significantly lower in the SP compared to the TP, approaching the physiological optimum of the healthy subjects. The WSS gradient showed significantly different values in the four proximally localized contours when comparing both prostheses with healthy subjects. Strong correlations between an elevated WSS gradient and secondary flow patterns were found in the ascending aorta and the aortic arch. Conclusion: Overall, the SP has a positive impact on WSS, most pronounced at the site and adjacent to the prosthesis. The WSS gradient differed most obviously and the correlation of the WSS gradient with the occurrence of secondary flow patterns provides further evidence for linking disturbed flow, which was markedly increased in patients compared to healthy sub jects, to degenerative remodeling of the vascular wall.

Original languageEnglish
Article number59
JournalJournal of Cardiovascular Magnetic Resonance
Volume22
Issue number1
Pages (from-to)59
ISSN1097-6647
DOIs
Publication statusPublished - 10.08.2020

Research Areas and Centers

  • Academic Focus: Biomedical Engineering
  • Centers: Cardiological Center Luebeck (UHZL)

DFG Research Classification Scheme

  • 205-30 Radiology, Nuclear Medicine, Radiation Therapy and Radiobiology

Fingerprint

Dive into the research topics of '4D flow CMR analysis comparing patients with anatomically shaped aortic sinus prostheses, tube prostheses and healthy subjects introducing the wall shear stress gradient: A case control study'. Together they form a unique fingerprint.

Cite this