Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Variations in performance characteristics of commercial enzyme immunoassay kits for detection of antineutrophil cytoplasmic antibodies: What is the optimal cut off?

J. U. Holle, B. Hellmich, M. Backes, W. L. Gross, Elena Csernok*

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

Background: Previous studies have shown considerable variation in diagnostic performance of enzyme linked immunosorbent assays (ELISAs) for measuring antineutrophil cytoplasmic antibodies (ANCA) specific for proteinase 3 (PR3) and myeloperoxidase (MPO). Objective: To analyse the performance characteristics of different commercially available direct ANCA ELISA kits. Methods: ELISA kits for detecting PR3-ANCA and MPO-ANCA from 11 manufacturers were evaluated. Serum samples were taken from patients with Wegener's granulomatosis (15), microscopic polyangiitis (15), other vasculitides (10), and controls (40). Results were compared with data obtained by indirect immunofluorescence (IFT). The diagnostic performance of the tests was analysed and compared by receiver operating characteristic (ROC) curve analysis. Results: Applying the manufacturers' cut off resulted in great variation in sensitivity of the commercial PR3-ANCA kits for diagnosing Wegener's granulomatosis (ranging from 13.3% to 66.7%), and of the MPO-ANCA kits for diagnosing microscopic polyangiitis (ranging from 26.7% to 66.7%). Specificities were relatively constant (from 96.0% to 100%). IFT was superior to all ELISAs (C-ANCA for Wegener's granulomatosis: sensitivity 73.3%, specificity 98%; P-ANCA for microscopic polyangiitis: sensitivity 86.7%, specificity 98%). The sensitivities of PR3-ANCA and MPO-ANCA ELISA kits were increased by lowering the cut off values. This reduced specificity but increased overall diagnostic performance. Conclusions: The low sensitivity of some commercial kits reflects the high cut off levels recommended rather than methodological problems with the assays. Comparative analyses using sera from well characterised patients may help identify optimum cut off levels of commercial ANCA ELISA tests, resulting in better comparability of results among assays from different manufacturers.

OriginalspracheEnglisch
ZeitschriftAnnals of the Rheumatic Diseases
Jahrgang64
Ausgabenummer12
Seiten (von - bis)1773-1779
Seitenumfang7
ISSN0003-4967
DOIs
PublikationsstatusVeröffentlicht - 12.2005

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen

Strategische Forschungsbereiche und Zentren

  • Forschungsschwerpunkt: Infektion und Entzündung - Zentrum für Infektions- und Entzündungsforschung Lübeck (ZIEL)

Fingerprint

Untersuchen Sie die Forschungsthemen von „Variations in performance characteristics of commercial enzyme immunoassay kits for detection of antineutrophil cytoplasmic antibodies: What is the optimal cut off?“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren