The value of indirect immunofluorescence and solid phase techniques for ANCA detection. A report on the first phase of an international cooperative study on the standardization of ANCA assays

E. Christiaan Hagen*, Konrad Andrassy, Elema Chernok, Mohammed R. Daha, Gill Gaskin, Wolfgang Gross, Philip Lesavre, Jens Lüdemann, Charles D. Pusey, Niels Rasmussen, Caroline O.S. Savage, Alberto Sinico, Allan Wiik, Fokko J. van der Woude

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

This study describes the results of phase I of an international effort to develop and standardize assays for the detection of anti-neutrophil cytoplasmic antibodies (ANCA). 12 sera, four of which were selected for their potential to cause problems in the detection of various ANCA specificities, were analyzed in the standard indirect immunofluorescence (IIF) test and in ELISAs for ANCA routinely performed in the seven participating laboratories. The IIF methodology differed with respect to the dilution of the serum being screened and the concentration of the conjugate used. Results from sera with high ANCA titers were similar, although the quantitative values could not be compared. In sera containing rheumatoid factor and anti-nuclear antibodies (ANA), ANCA-unrelated staining patterns were observed. Six antigen preparations were used in ELISA for the detection of cANCA. In ELISA with purified proteinase-3 all three cANCA sera were positive, but not anti-myeloperoxidase (MPO) or anti-lactoferrin (LF) positive sera. The other assays were less sensitive or gave inconsistent results. Various preparations of purified MPO and LF used in ELISA were readily recognized by anti-MPO and anti-LF positive sera. From this study it can be concluded that the IIF test, although performed with different methods, shows comparable results using strongly positive sera. In general solid phase assays for cANCA detection are not well standardized and need improvement although the purified proteinase-3 ELISA is possibly an exception. MPO and LF can be used in ELISA procedures for the detection of pANCA-related antibodies.

OriginalspracheEnglisch
ZeitschriftJournal of Immunological Methods
Jahrgang159
Ausgabenummer1-2
Seiten (von - bis)1-16
Seitenumfang16
ISSN0022-1759
DOIs
PublikationsstatusVeröffentlicht - 26.02.1993

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen

Strategische Forschungsbereiche und Zentren

  • Forschungsschwerpunkt: Infektion und Entzündung - Zentrum für Infektions- und Entzündungsforschung Lübeck (ZIEL)

Fingerprint

Untersuchen Sie die Forschungsthemen von „The value of indirect immunofluorescence and solid phase techniques for ANCA detection. A report on the first phase of an international cooperative study on the standardization of ANCA assays“. Zusammen bilden sie einen einzigartigen Fingerprint.