Simulation of mammographic breast compression in 3D MR images using ICP-based B-spline deformation for multimodality breast cancer diagnosis

Julia Krüger*, Jan Ehrhardt, Arpad Bischof, Heinz Handels

*Korrespondierende/r Autor/-in für diese Arbeit
4 Zitate (Scopus)

Abstract

Purpose: Multimodality mammography using conventional 2D mammography and dynamic contrast-enhanced 3D magnetic resonance imaging (DCE-MRI) is frequently performed for breast cancer detection and diagnosis. Combination of both imaging modalities requires superimposition of corresponding structures in mammograms and MR images. This task is challenging due to large differences in (1) dimensionality and spatial resolution, (2) variations in tissue contrast, as well as (3) differences in breast orientation and deformation during the image acquisition. A new method for multimodality breast image registration was developed and tested. Methods: Combined diagnosis of mammograms and MRI datasets was achieved by simulation of mammographic breast compression to overcome large differences in breast deformation. Surface information was extracted from the 3D MR image, and back-projection of the 2D breast contour in the mammogram was done. B-spline-based 3D/3D surface-based registration was then used to approximate mammographic breast compression. This breast deformation simulation was performed on 14 MRI datasets with 19 corresponding mammograms. The results were evaluated by comparison with distances between corresponding structures identified by an expert observer. Results: The evaluation revealed an average distance of 6.46 mm between corresponding structures, when an optimized initial alignment between both image datasets is performed. Without the optimization, the accuracy is 9.12 mm. Conclusion: A new surface-based method that approximates the mammographic deformation due to breast compression without using a specific complex model needed for finite-element-based methods was developed and tested with favorable results. The simulated compression can serve as foundation for a point-to-line correspondence between 2D mammograms and 3D MR image data.

OriginalspracheEnglisch
ZeitschriftInternational Journal of Computer Assisted Radiology and Surgery
Jahrgang9
Ausgabenummer3
Seiten (von - bis)367-377
Seitenumfang11
ISSN1861-6410
DOIs
PublikationsstatusVeröffentlicht - 01.01.2014

Fingerprint

Untersuchen Sie die Forschungsthemen von „Simulation of mammographic breast compression in 3D MR images using ICP-based B-spline deformation for multimodality breast cancer diagnosis“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren