Shoulder and Knee Arthroscopy Access Point: Prospective Comparison of Sonographic and Palpatory Detection – Which Method is Better for Novices?

Andreas Michael Weimer, Johannes M. Weimer*, Svenja Berthold, Stephan Stein, Lukas Müller, Holger Buggenhagen, Gerd Balser, Kay Stankov, Mirco Sgroi, Gerhard Schmidmaier, Roman Kloeckner, Christian Schamberger

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

Purpose Arthroscopy is one of the most common interventions in orthopedics. Hence it is important to train users early in order to ensure the safest possible identification of access portals (AP). This prospective study aimed to compare a palpatory (PalpMethod) with a sonographic (SonoMethod) method for AP location in the shoulder and knee joints. Materials and Methods The study included trainee doctors (n = 68) attending workshops (lasting approx. 90 minutes). In these workshops a teaching video initially demonstrated the PalpMethod and SonoMethod of AP identification. An experienced operator first marked the access portals on the test subject with a UV pen (determined ideal point [DIP]). Adhesive film was then affixed to the puncture regions. Subsequently participants marked on shoulders and knees first the point determined by palpation, then the point determined by sonography. Analysis involved DIP visualization with a UV lamp and employed a coordinate system around the central DIP. In addition, participants completed an evaluation before and after the workshop. Results The analysis included 324 measurements (n = 163 shoulders and n = 161 knees). The majority of participants had not previously attended any courses on manual examination (87.9 %) or musculoskeletal ultrasound (93.9 %). Overall, the markings participants made on the shoulder using the SonoMethod were significantly closer to the DIP than those made by the PalpMethod (Palp 18.8mm ± 14.5mm vs. Sono 11.2mm ± 7.2mm; p < 0.001). On the knee, however, the markings made by the PalpMethod were significantly closer to the DIP overall (Palp 8.0mm ± 3.2mm vs. Sono 12.8mm ± 5.2mm; p < 0.001). Conclusion The results show that the SonoMethod produces more accurate markings on the shoulder, while the PalpMethod is superior for the knee.

OriginalspracheEnglisch
ZeitschriftUltrasound International Open
Jahrgang10
Seiten (von - bis)23-29
Seitenumfang7
ISSN2509-596X
DOIs
PublikationsstatusVeröffentlicht - 06.11.2023

Fingerprint

Untersuchen Sie die Forschungsthemen von „Shoulder and Knee Arthroscopy Access Point: Prospective Comparison of Sonographic and Palpatory Detection – Which Method is Better for Novices?“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren