TY - JOUR
T1 - Selective equatorial sclera crosslinking in the orbit using a metal-coated polymer waveguide
AU - Kwok, Sheldon J.J.
AU - Forward, Sarah
AU - Wertheimer, Christian M.
AU - Liapis, Andreas C.
AU - Lin, Harvey H.
AU - Kim, Moonseok
AU - Seiler, Theo
AU - Birngruber, Reginald
AU - Kochevar, Irene E.
AU - Seiler, Theo
AU - Yun, Seok Hyun
N1 - Funding Information:
Supported by National Institutes of Health (Bethesda, MD, USA) Grants R01-EY025454, R41EY028820, and P41-EB015903, and the U.S. Air Force Office of Scientific Research (FA9550-17-1-0277). This research used resources of the Center for Functional Nanomaterials, which is a U.S. DOE Office of Science Facility, at Brookhaven National Laboratory under Contract No. DESC0012704.
Publisher Copyright:
© 2019, Association for Research in Vision and Ophthalmology Inc.. All rights reserved.
Copyright:
Copyright 2019 Elsevier B.V., All rights reserved.
PY - 2019/6
Y1 - 2019/6
N2 - PURPOSE. Photochemical crosslinking of the sclera is an emerging technique that may prevent excessive eye elongation in pathologic myopia by stiffening the scleral tissue. To overcome the challenge of uniform light delivery in an anatomically restricted space, we previously introduced the use of flexible polymer waveguides. We presently demonstrate advanced waveguides that are optimized to deliver light selectively to equatorial sclera in the intact orbit. METHODS. Our waveguides consist of a polydimethylsiloxane cladding and a polyurethane core, coupled to an optical fiber. A reflective silver coating deposited on the top and side surfaces of the waveguide prevents light leakage to nontarget, periorbital tissue. Postmortem rabbits were used to test the feasibility of in situ equatorial sclera crosslinking. Tensometry measurements were performed on ex vivo rabbit eyes to confirm a biomechanical stiffening effect. RESULTS. Metal-coated waveguides enabled efficient light delivery to the entire circumference of the equatorial sclera with minimal light leakage to the periorbital tissues. Blue light was delivered to the intact orbit with a coefficient of variation in intensity of 22%, resulting in a 45 ± 11% bleaching of riboflavin fluorescence. A 2-fold increase in the Young’s modulus at 5% strain (increase of 92% P < 0.05, at 25 J/cm2) was achieved for ex vivo crosslinked eyes. CONCLUSIONS. Flexible polymer waveguides with reflective, biocompatible surfaces are useful for sclera crosslinking to achieve targeted light delivery. We anticipate that our demonstrated procedure will be applicable to sclera crosslinking in live animal models and, potentially, humans in vivo.
AB - PURPOSE. Photochemical crosslinking of the sclera is an emerging technique that may prevent excessive eye elongation in pathologic myopia by stiffening the scleral tissue. To overcome the challenge of uniform light delivery in an anatomically restricted space, we previously introduced the use of flexible polymer waveguides. We presently demonstrate advanced waveguides that are optimized to deliver light selectively to equatorial sclera in the intact orbit. METHODS. Our waveguides consist of a polydimethylsiloxane cladding and a polyurethane core, coupled to an optical fiber. A reflective silver coating deposited on the top and side surfaces of the waveguide prevents light leakage to nontarget, periorbital tissue. Postmortem rabbits were used to test the feasibility of in situ equatorial sclera crosslinking. Tensometry measurements were performed on ex vivo rabbit eyes to confirm a biomechanical stiffening effect. RESULTS. Metal-coated waveguides enabled efficient light delivery to the entire circumference of the equatorial sclera with minimal light leakage to the periorbital tissues. Blue light was delivered to the intact orbit with a coefficient of variation in intensity of 22%, resulting in a 45 ± 11% bleaching of riboflavin fluorescence. A 2-fold increase in the Young’s modulus at 5% strain (increase of 92% P < 0.05, at 25 J/cm2) was achieved for ex vivo crosslinked eyes. CONCLUSIONS. Flexible polymer waveguides with reflective, biocompatible surfaces are useful for sclera crosslinking to achieve targeted light delivery. We anticipate that our demonstrated procedure will be applicable to sclera crosslinking in live animal models and, potentially, humans in vivo.
UR - http://www.scopus.com/inward/record.url?scp=85068448721&partnerID=8YFLogxK
U2 - 10.1167/iovs.19-26709
DO - 10.1167/iovs.19-26709
M3 - Journal articles
C2 - 31212308
AN - SCOPUS:85068448721
SN - 0146-0404
VL - 60
SP - 2563
EP - 2570
JO - Investigative Ophthalmology and Visual Science
JF - Investigative Ophthalmology and Visual Science
IS - 7
ER -