Abstract
Background: Dilative cardiomyopathy is an uncommon cardiac complication of electric shock. Case presentation: We report a case of a 12-year-old German boy with a high voltage injury who developed a four-chamber dilative cardiomyopathy, which was diagnosed on the 13th week postburn. One year after the accident, echocardiography showed a normal function of his heart with 64% ejection fraction and normal cavities' dimensions. Conclusions: Despite the fact that dilative cardiomyopathy is not very common in electrical injuries but can be fatal, a prolonged echocardiography follow-up for patients with electrical injury could be recommended. Until now this case is the first child with severe burns after electrocution, who developed a reversible dilative cardiomyopathy.
| Originalsprache | Englisch |
|---|---|
| Aufsatznummer | 333 |
| Zeitschrift | Journal of Medical Case Reports |
| Jahrgang | 12 |
| Ausgabenummer | 1 |
| ISSN | 1752-1947 |
| DOIs | |
| Publikationsstatus | Veröffentlicht - 08.11.2018 |