Retinal polarization-sensitive optical coherence tomography at 1060 nm with 350 kHz A-scan rate using an Fourier domain mode locked laser

  • Teresa Torzicky*
  • , Sebastian Marschall
  • , Michael Pircher
  • , Bernhard Baumann
  • , Marco Bonesi
  • , Stefan Zotter
  • , Erich Götzinger
  • , Wolfgang Trasischker
  • , Thomas Klein
  • , Wolfgang Wieser
  • , Benjamin Biedermann
  • , Robert Huber
  • , Peter Andersen
  • , Christoph K. Hitzenberger
  • *Korrespondierende/r Autor/-in für diese Arbeit
  • Center for Medical Physics and Biomedical Engineering
  • University of Vienna
  • DTU Fotonik, Department of Photonics Engineering
  • DTU Informatics, Technical University of Denmark
  • Lehrstuhl für Biomolekulare Optik
  • Ludwig-Maximilians-Universität

Abstract

We present a novel, high-speed, polarization-sensitive, optical coherence tomography set-up for retinal imaging operating at a central wavelength of 1060 nm which was tested for in vivo imaging in healthy human volunteers. We use the system in combination with a Fourier domain mode locked laser with active spectral shaping which enables the use of forward and backward sweep in order to double the imaging speed without a buffering stage. With this approach and with a custom designed data acquisition system, we show polarization-sensitive imaging with an A-scan rate of 350 kHz. The acquired three-dimensional data sets of healthy human volunteers show different polarization characteristics in the eye, such as depolarization in the retinal pigment epithelium and birefringence in retinal nerve fiber layer and sclera. The increased speed allows imaging of large volumes with reduced motion artifacts. Moreover, averaging several two-dimensional frames allows the generation of high-definition B-scans without the use of an eye-tracking system. The increased penetration depth of the system, which is caused by the longer probing beam wavelength, is beneficial for imaging choroidal and scleral structures and allows automated segmentation of these layers based on their polarization characteristics.

OriginalspracheEnglisch
Aufsatznummer026008
ZeitschriftJournal of Biomedical Optics
Jahrgang18
Ausgabenummer2
ISSN1083-3668
DOIs
PublikationsstatusVeröffentlicht - 01.02.2013

Fördermittel

Financial support from the European Union (project FUN OCT, FP7 HEALTH, Contract No. 201880) and from the Austrian Science Fund (FWF Grant P19624-B02) is gratefully acknowledged. The authors acknowledge the supply of SOAs deployed in the FDML laser from Exalos GmbH.

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen
  2. SDG 9 – Industrie, Innovation und Infrastruktur
    SDG 9 – Industrie, Innovation und Infrastruktur

Fingerprint

Untersuchen Sie die Forschungsthemen von „Retinal polarization-sensitive optical coherence tomography at 1060 nm with 350 kHz A-scan rate using an Fourier domain mode locked laser“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren