T1 - Replacement of implantable cardioverter defibrillators and cardiac resynchronization therapy devices
T2 - results of the European Heart Rhythm Association survey
AU - Tilz, Roland
AU - Boveda, Serge
AU - Deharo, Jean Claude
AU - Dobreanu, Dan
AU - Haugaa, Kristina H.
AU - Dagres, Nikolaos
N1 - Publisher Copyright:
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: [email protected].
PY - 2016/6/1
Y1 - 2016/6/1
N2 - The aim of this EP Wire was to assess the management, indications, and techniques for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) device replacement in Europe. A total of 24 centres in 14 European countries completed the questionnaire. All centres were members of the European Heart Rhythm Association Electrophysiology Research Network. Replacement procedures were performed by electrophysiologists in 52% of the centres, by cardiologists in 33%, and both in the remaining centres. In the majority of centres, the procedures were performed during a short hospitalization (<2 days; 61.2%), or on an outpatient basis (28%). The overwhelming majority of centres reported that they replaced ICDs at the end of battery life. Only in a small subset (<10%) of patients with ICD for primary prevention and without ventricular tachycardia (VT) since implantation, ICD was not replaced. In inherited primary arrhythmia syndromes, 80% of the centres always replaced the ICD at the end of battery life. After VT ablation, only few centres (9%) explanted or downgraded the device that was previously implanted for secondary prevention, but only in those patients without new VT episodes. Patient's life expectancy <1 year was the most commonly reported reason (61%) to downgrade from a CRT-D to a CRT-P device. While warfarin therapy was continued in 47% of the centres, non-vitamin K oral anticoagulants were discontinued without bridging 24 h prior to replacement procedures in 60%. Finally, in 65% of the centres, VT induction and shock testing during ICD and CRT-D replacement were performed only in the case of leads with a warning or with borderline measurements. This survey provides a snapshot of the perioperative management, indications, and techniques of ICD and CRT device replacement in Europe. It demonstrates some variations between participating centres, probably related to local policies and to the heterogeneity of the ICD population.
AB - The aim of this EP Wire was to assess the management, indications, and techniques for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) device replacement in Europe. A total of 24 centres in 14 European countries completed the questionnaire. All centres were members of the European Heart Rhythm Association Electrophysiology Research Network. Replacement procedures were performed by electrophysiologists in 52% of the centres, by cardiologists in 33%, and both in the remaining centres. In the majority of centres, the procedures were performed during a short hospitalization (<2 days; 61.2%), or on an outpatient basis (28%). The overwhelming majority of centres reported that they replaced ICDs at the end of battery life. Only in a small subset (<10%) of patients with ICD for primary prevention and without ventricular tachycardia (VT) since implantation, ICD was not replaced. In inherited primary arrhythmia syndromes, 80% of the centres always replaced the ICD at the end of battery life. After VT ablation, only few centres (9%) explanted or downgraded the device that was previously implanted for secondary prevention, but only in those patients without new VT episodes. Patient's life expectancy <1 year was the most commonly reported reason (61%) to downgrade from a CRT-D to a CRT-P device. While warfarin therapy was continued in 47% of the centres, non-vitamin K oral anticoagulants were discontinued without bridging 24 h prior to replacement procedures in 60%. Finally, in 65% of the centres, VT induction and shock testing during ICD and CRT-D replacement were performed only in the case of leads with a warning or with borderline measurements. This survey provides a snapshot of the perioperative management, indications, and techniques of ICD and CRT device replacement in Europe. It demonstrates some variations between participating centres, probably related to local policies and to the heterogeneity of the ICD population.
UR - http://www.scopus.com/inward/record.url?scp=85026721740&partnerID=8YFLogxK
U2 - 10.1093/europace/euw157
DO - 10.1093/europace/euw157
M3 - Journal articles
C2 - 27297231
AN - SCOPUS:85026721740
SN - 1099-5129
VL - 18
SP - 945
EP - 949
JO - Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
JF - Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
IS - 6
ER -