Rapid study assessment in follow-up whole-body computed tomography in patients with multiple myeloma using a dedicated bone subtraction software

M. M. Sieren*, F. Brenne, A. Hering, H. Kienapfel, N. Gebauer, T. H. Oechtering, A. Fürschke, F. Wegner, E. Stahlberg, S. Heldmann, J. Barkhausen, A. Frydrychowicz

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

OBJECTIVES: The diagnostic reading of follow-up low-dose whole-body computed tomography (WBCT) examinations in patients with multiple myeloma (MM) is a demanding process. This study aimed to evaluate the diagnostic accuracy and benefit of a novel software program providing rapid-subtraction maps for bone lesion change detection.

METHODS: Sixty patients (66 years ± 10 years) receiving 120 WBCT examinations for follow-up evaluation of MM bone disease were identified from our imaging archive. The median follow-up time was 292 days (range 200-641 days). Subtraction maps were calculated from 2-mm CT images using a nonlinear deformation algorithm. Reading time, correctly assessed lesions, and disease classification were compared to a standard reading software program. De novo clinical reading by a senior radiologist served as the reference standard. Statistics included Wilcoxon rank-sum test, Cohen's kappa coefficient, and calculation of sensitivity, specificity, positive/negative predictive value, and accuracy.

RESULTS: Calculation time for subtraction maps was 84 s ± 24 s. Both readers reported exams faster using subtraction maps (reader A, 438 s ± 133 s; reader B, 1049 s ± 438 s) compared to PACS software (reader A, 534 s ± 156 s; reader B, 1486 s ± 587 s; p < 0.01). The course of disease was correctly classified by both methods in all patients. Sensitivity for lesion detection in subtraction maps/conventional reading was 92%/80% for reader A and 88%/76% for reader B. Specificity was 98%/100% for reader A and 95%/96% for reader B.

CONCLUSION: A software program for the rapid-subtraction map calculation of follow-up WBCT scans has been successfully tested and seems suited for application in clinical routine. Subtraction maps significantly facilitated reading of WBCTs by reducing reading time and increasing sensitivity.

KEY POINTS: • A novel algorithm has been successfully applied to generate motion-corrected bone subtraction maps of whole-body low-dose CT scans in less than 2 min. • Motion-corrected bone subtraction maps significantly facilitate the reading of follow-up whole-body low-dose CT scans in multiple myeloma by reducing reading time and increasing sensitivity.

OriginalspracheEnglisch
ZeitschriftEuropean Radiology
Jahrgang30
Ausgabenummer6
Seiten (von - bis)3198-3209
Seitenumfang12
ISSN0938-7994
DOIs
PublikationsstatusVeröffentlicht - 01.06.2020

Strategische Forschungsbereiche und Zentren

  • Forschungsschwerpunkt: Biomedizintechnik

DFG-Fachsystematik

  • 2.22-30 Radiologie

Fingerprint

Untersuchen Sie die Forschungsthemen von „Rapid study assessment in follow-up whole-body computed tomography in patients with multiple myeloma using a dedicated bone subtraction software“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren