Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Abstract

Background Few prospective series have described the safety and effectiveness of the Neuroform Atlas Stent System. We aimed to investigate the efficacy and safety of the device in patients treated for unruptured aneurysm. Methods ATLAS EU PMCF is a consecutive, prospective, multicentric study that included patients with unruptured saccular aneurysm of all sizes. Follow-up visits were scheduled at 3–6 months and 12–16 months with digital subtraction angiography (DSA) or MRI imaging followup as per the site standard of care. The primary efficacy endpoint was adequate aneurysm occlusion (Raymond Roy occlusion grade I and II) on 12 month angiography. The primary safety endpoint was any major stroke or ipsilateral stroke or neurological death within 12 months. Results Of the 106 patients consented, 105 were treated with at least one Neuroform Atlas stent. There was a failed implantation attempt in 1 patient, 85 patients received lateral stenting, and 19 patients received Y-stenting. Mean aneurysm neck size was 4.2 mm (range 1.9–33 mm). Adequate occlusion was observed in 95.1% immediately after the procedure and in 98.9% of cases at 1 year DSA follow-up. Overall, 1.0% (1/102; 95% CI 0.0% to 5.3%) of patients experienced a primary safety endpoint of major stroke. Three minor strokes resulted in a modified Rankin Scale score of 2. Conclusions In this multicentric, prospective study, stent-assisted coiling of medium size unruptured aneurysms with the Neuroform Atlas stent resulted in a favorable rate of satisfactory occlusion. In our findings, the use of the Y-stenting technique was associated with increased rates of procedural complications.

OriginalspracheEnglisch
ZeitschriftJournal of NeuroInterventional Surgery
Jahrgang14
Ausgabenummer7
Seiten (von - bis)694-698
Seitenumfang5
ISSN1759-8478
DOIs
PublikationsstatusVeröffentlicht - 07.2022

Fördermittel

Funding The ATLAS EU PMCF study (Evaluation of Safety and Performance of the Neuroform Atlas™ Stent System for Intracranial Aneurysm Treatment – Post Market Clinical Follow-up) was funded by Stryker Neurovascular (Fremont, California, United States).

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen
  2. SDG 9 – Industrie, Innovation und Infrastruktur
    SDG 9 – Industrie, Innovation und Infrastruktur

Strategische Forschungsbereiche und Zentren

  • Forschungsschwerpunkt: Gehirn, Hormone, Verhalten - Center for Brain, Behavior and Metabolism (CBBM)

DFG-Fachsystematik

  • 2.23-07 Klinische Neurologie, Neurochirurgie und Neuroradiologie

Fingerprint

Untersuchen Sie die Forschungsthemen von „Multi-centric European post-market follow-up study of the Neuroform Atlas Stent System: primary results“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren