Modified Eulers Elastica Inpainting for Metal Artifact Reduction in CT

Julia Hamer, Bärbel Kratz, Jan Müller, Thorsten M. Buzug

Abstract

In computed tomography (CT) metal causes strong streak artifacts in the reconstructed images, which may hinder the correct diagnosis of patients. In this work, metal artifacts are reduced using the modified Eulers elastica and curvature based sinogram inpainting (EECSI). The inconsistent data is deleted from the sinogram and replaced by a two-dimensional interpolation strategy based on the surrounding data information using partial differential equations. The inpainting domain is defined by a binary mask that is calculated using a thresholding method in the preliminary reconstructed image with a following forward projection of the metal-only image. Here, the EECSI is modified by a statistic weighting function that regulates the time step size depending on the probability of a gray value. Additionally, the connectivity principle is strengthened by applying a different strategy in the numerical implementation compared to prior methods. The measurements are realized on a Philips Tomoscan M/EG scanner using a torso phantom with the physical properties of an average male torso, suitable for medical experiments. For evaluation, the results are compared to the ones achieved by using the original EECSI and the classically used one-dimensional linear interpolation method. It is demonstrated that the performed modifications result in a better metal artifact suppression.
OriginalspracheEnglisch
TitelBildverarbeitung für die Medizin 2012
Redakteure/-innenThomas Tolxdorff, Thomas Martin Deserno, Heinz Handels, Hans-Peter Meinzer
Seitenumfang6
Herausgeber (Verlag)Springer Berlin Heidelberg
Erscheinungsdatum16.03.2012
Seiten310-315
ISBN (Print)978-3-642-28501-1
ISBN (elektronisch)978-3-642-28502-8
DOIs
PublikationsstatusVeröffentlicht - 16.03.2012
VeranstaltungWorkshop on Bildverarbeitung fur die Medizin 2012 - Berlin, Deutschland
Dauer: 18.03.201220.03.2012

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen
  2. SDG 9 – Industrie, Innovation und Infrastruktur
    SDG 9 – Industrie, Innovation und Infrastruktur

Fingerprint

Untersuchen Sie die Forschungsthemen von „Modified Eulers Elastica Inpainting for Metal Artifact Reduction in CT“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren