Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Microscopic optical coherence tomography (mOCT) at 600 kHz for 4D volumetric imaging and dynamic contrast

MICHAEL MUNTER*, MARIO PIEPER, TABEA KOHLFAERBER, ERNST BODENSTORFER, MARTIN AHRENS, CHRISTIAN WINTER, ROBERT HUBER, PETER KONIG, GEREON HUTTMANN, HINNERK SCHULZ-HILDEBRANDT

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

Volumetric imaging of dynamic processes with microscopic resolution holds a huge potential in biomedical research and clinical diagnosis. Using supercontinuum light sources and high numerical aperture (NA) objectives, optical coherence tomography (OCT) achieves microscopic resolution and is well suited for imaging cellular and subcellular structures of biological tissues. Currently, the imaging speed of microscopic OCT (mOCT) is limited by the line-scan rate of the spectrometer camera and ranges from 30 to 250 kHz. This is not fast enough for volumetric imaging of dynamic processes in vivo and limits endoscopic application. Using a novel CMOS camera, we demonstrate fast 3-dimensional OCT imaging with 600,000 A-scans/s at 1.8 μm axial and 1.1 μm lateral resolution. The improved speed is used for imaging of ciliary motion and particle transport in ex vivo mouse trachea. Furthermore, we demonstrate dynamic contrast OCT by evaluating the recorded volumes rather than en face planes or B-scans. High-speed volumetric mOCT will enable the correction of global tissue motion and is a prerequisite for applying dynamic contrast mOCT in vivo. With further increase in imaging speed and integration in flexible endoscopes, volumetric mOCT may be used to complement or partly replace biopsies.

OriginalspracheEnglisch
ZeitschriftBiomedical Optics Express
Jahrgang12
Ausgabenummer10
Seiten (von - bis)6024-6039
Seitenumfang16
DOIs
PublikationsstatusVeröffentlicht - 01.10.2021

Fördermittel

Funding. German Science Foundation (EXC 2167, RA1771/4-1); Ministry of Research, Innovation and Science (13GW0228A), Helmholtz Center Munich of Health and Environment DZL-ARCN (82DZL001A2); European Union project within Interreg Deutschland-Denmark from the European Regional Development Fund (CELLTOM).

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen
  2. SDG 9 – Industrie, Innovation und Infrastruktur
    SDG 9 – Industrie, Innovation und Infrastruktur

Fingerprint

Untersuchen Sie die Forschungsthemen von „Microscopic optical coherence tomography (mOCT) at 600 kHz for 4D volumetric imaging and dynamic contrast“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren