Learning three-dimensional aortic root assessment based on sparse annotations

Johanna Brosig*, Nina Krüger, Isaac Wamala, Matthias Ivantsits, Simon Sündermann, Jörg Kempfert, Stefan Heldmann, Anja Hennemuth

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

Purpose: Analyzing the anatomy of the aorta and left ventricular outflow tract (LVOT) is crucial for risk assessment and planning of transcatheter aortic valve implantation (TAVI). A comprehensive analysis of the aortic root and LVOT requires the extraction of the patient-individual anatomy via segmentation. Deep learning has shown good performance on various segmentation tasks. If this is formulated as a supervised problem, large amounts of annotated data are required for training. Therefore, minimizing the annotation complexity is desirable.

Approach: We propose two-dimensional (2D) cross-sectional annotation and point cloud-based surface reconstruction to train a fully automatic 3D segmentation network for the aortic root and the LVOT. Our sparse annotation scheme enables easy and fast training data generation for tubular structures such as the aortic root. From the segmentation results, we derive clinically relevant parameters for TAVI planning.

Results: The proposed 2D cross-sectional annotation results in high inter-observer agreement [Dice similarity coefficient (DSC): 0.94]. The segmentation model achieves a DSC of 0.90 and an average surface distance of 0.96 mm. Our approach achieves an aortic annulus maximum diameter difference between prediction and annotation of 0.45 mm (inter-observer variance: 0.25 mm).

Conclusions: The presented approach facilitates reproducible annotations. The annotations allow for training accurate segmentation models of the aortic root and LVOT. The segmentation results facilitate reproducible and quantifiable measurements for TAVI planning.

Keywords: annotation; aortic root; left ventricular outflow tract; segmentation; transcatheter aortic valve implantation.
OriginalspracheEnglisch
TitelMedical Imaging 2024
BandVol. 11, no. 4
Erscheinungsdatum30.07.2024
DOIs
PublikationsstatusVeröffentlicht - 30.07.2024

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 9 – Industrie, Innovation und Infrastruktur
    SDG 9 – Industrie, Innovation und Infrastruktur

Fingerprint

Untersuchen Sie die Forschungsthemen von „Learning three-dimensional aortic root assessment based on sparse annotations“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren