Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Intra- und postoperatives Monitoring von Lappentransplantaten. Messung des Gewebesauerstoffpartialdrucks.

O. Driemel*, I. Oberfahrenhorst, S. G. Hakim, H. Kosmehl, H. Pistner

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

BACKGROUND: According to Schmelzeisen et al. (1996), the failure rate for microvascular free flaps is 5%. While surface tissue oxygenation can be assessed clinically, if necessary by a puncture, the oxygen supply to deeper areas mostly cannot be checked. We therefore wished to find whether measurement of tissue pO(2) would prove to be an objective and practical technique that could be used for continuous and accurate intra- and postoperative evaluation of flap perfusion. MATERIAL AND METHODS: A Clark-type microcatheter was used intra- and postoperatively to monitor tissue pO(2) in 5 pedicled pectoralis major flaps and 32 free revascularized flaps (9 jejunal flaps, 5 latissimus dorsi flaps, 6 radial forearm flaps and 12 scapular flaps). RESULTS: The mean values for tissue pO(2) were significantly lower in pedicle grafts than in free revascularized flaps. Within in each flap group the pO(2) values measured did not vary significantly over an observation period of up to 77.2 h after transplantation. CONCLUSIONS: Continuous measurement of tissue pO(2) by means of a Clark-type microcatheter combined with clinical examination constitutes a reliable method of monitoring tissue oxygenation in pedicle grafts and free revascularized flaps during the intra- and postoperative phases. Analysis of small and of wide fluctuations in pO(2) values may help in the diagnosis of early arterial and venous obstructions in flaps and may in the future result in new insights into the tissue oxygenation in surgical flaps allowing some alleviation of the problems currently experienced in clinical monitoring.

Titel in ÜbersetzungIntra- and postoperative monitoring of transplanted flaps. Measurement of the partial pressure of oxygen in tissue
OriginalspracheDeutsch
ZeitschriftMund-, Kiefer- und Gesichtschirurgie : MKG
Jahrgang8
Ausgabenummer6
Seiten (von - bis)361-368
Seitenumfang8
ISSN1432-9417
DOIs
PublikationsstatusVeröffentlicht - 11.2004

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen

Fingerprint

Untersuchen Sie die Forschungsthemen von „Intra- und postoperatives Monitoring von Lappentransplantaten. Messung des Gewebesauerstoffpartialdrucks.“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren