Influence of different infracardial positions of central venous catheters in hemodynamic monitoring using the transpulmonal thermodilution method

Patrick Kellner, Viola Schleusener, Frank Bauerfeind, Jens Soukup*

*Korrespondierende/r Autor/-in für diese Arbeit
4 Zitate (Scopus)

Abstract

Hemodynamic measurements are often conducted by the transpulmonary thermodilution (TPTD)-based PiCCO®-system. This requires a central-venous (CVC) and a thermistor-tipped arterial catheter, usually placed in the femoral artery. In certain clinical situations, CVC devices have to be placed in the inferior vena cava. However, little is known about the influence of different CVC positions (i.e. ipsi- vs. contra-lateral to the arterial catheter) on the accuracy of the TPTD measurement results. In this prospective observational study surgical intensive care unit patients who had been inserted with CVCs either into the superior (CVCVCS) or the inferior vena cava (CVCinf) in addition to an arterial PiCCO®-catheter, were enrolled. Patients were then divided into two groups: Group I was provided with a CVC in the contralateral (CVCcontra) and Group II in the ipsilateral (CVCipsi) inferior vena cava. Thermodilution via injection of ice-cold saline was then performed via CVCsup and CVCinf. Bland–Altman analysis for cardiac index (CI), extra-vascular lung water index (EVLWI) and global end-diastolic volume index (GEDVI) were employed. Additional correction formulas for femorally assed parameters were determined. In a total of 28 patients, bias (limits of agreement) for measurements of CI in CVCcontra was found to be +0.2 (−0.4; +0.9) and +0.3 (−0.4; +1.0) L/min/m2 in CVCipsi. GEDVI showed a bias of +274.8 (−47.3; +596.9) mL/m2 in CVCcontra and +274.7 (−100.7; +650.1) mL/m2 in CVCipsi. The mean EVLWI were 9.4 ± 4.3 mL/kg for EVLWIVCS and 10.7 ± 5.2 mL/kg for EVLWIinf. The LoA yielded at −3.4 and +6.1 mL/kg with a bias of +1.3 mL/kg. Percentage errors revealed clinically acceptable limits for CI and GEDVI, but not for EVLWI. Using TPTD via an infracardial central vein, measurements of CI showed high accuracy and precision while GEDVI measurements were precise with a lower accuracy, irrespective of the position of the infracardial CVC.

OriginalspracheEnglisch
ZeitschriftJournal of Clinical Monitoring and Computing
Jahrgang30
Ausgabenummer5
Seiten (von - bis)629-640
Seitenumfang12
ISSN1387-1307
DOIs
PublikationsstatusVeröffentlicht - 01.10.2016

Fingerprint

Untersuchen Sie die Forschungsthemen von „Influence of different infracardial positions of central venous catheters in hemodynamic monitoring using the transpulmonal thermodilution method“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren