Individualized or fixed approach to pulmonary vein isolation utilizing the fourth-generation cryoballoon in patients with paroxysmal atrial fibrillation: the randomized INDI-FREEZE trial

Christian Hendrik Heeger*, Sorin Stefan Popescu, Roza Saraei, Bettina Kirstein, Sascha Hatahet, Omar Samara, Anna Traub, Marcel Fehe, Gabriele D'Ambrosio, Ahmad Keelani, Michael Schlüter, Charlotte Eitel, Julia Vogler, Karl Heinz Kuck, Roland Richard Tilz*

*Korrespondierende/r Autor/-in für diese Arbeit
6 Zitate (Scopus)

Abstract

Aims: Cryoballoon (CB) based pulmonary vein isolation (PVI) is a widely used technique for treatment of atrial fibrillation (AF); however the ideal energy dosing has not yet been standardized. This was a single-centre randomized clinical trial aiming at assessing the safety, acute efficacy, and clinical outcome of an individualized vs. a fixed CB ablation protocol using the fourth-generation CB (CB4) guided by pulmonary vein (PV) potential recordings and CB temperature. Methods and results: Patients were randomized in a 1:1 fashion to two different dosing protocols: INDI-FREEZE group (individualized protocol): freeze-cycle duration of time to effect plus 90 s or interruption of the freeze-cycle and repositioning CB if a CB temperature of -30°C was not within 40 s. Control group (fixed protocol): freeze-cycle duration of 180 s. No-bonus freeze-cycle was applied in either patient group. The primary endpoint was freedom from atrial tachyarrhythmia at 12 months. Secondary end points included procedural parameters and complications. A total of 100 patients with paroxysmal AF were prospectively enrolled. No difference was seen in the primary endpoint [INDI-FREEZE group: 38/47 (81%) vs. control group: 40/47, (85%), P = 0.583]. The total freezing time was significantly shorter in the INDI-FREEZE group (157 ± 56 s vs. 212 ± 83 s, P < 0.001), while procedure duration (57.9 ± 17.9 min vs. 63.2 ± 20.2 min, P = 0.172) was similar. No differences were seen in the minimum CB and oesophageal temperatures as well as in periprocedural complications. Conclusion: Compared to the fixed protocol, the individualized approach provides a similar safety profile and clinical outcome, while reducing the total freezing time.

OriginalspracheEnglisch
ZeitschriftEuropace
Jahrgang24
Ausgabenummer6
Seiten (von - bis)921-927
Seitenumfang7
ISSN1099-5129
DOIs
PublikationsstatusVeröffentlicht - 01.06.2022

Strategische Forschungsbereiche und Zentren

  • Zentren: Universitäres Herzzentrum Lübeck (UHZL)

DFG-Fachsystematik

  • 2.22-12 Kardiologie, Angiologie

Fingerprint

Untersuchen Sie die Forschungsthemen von „Individualized or fixed approach to pulmonary vein isolation utilizing the fourth-generation cryoballoon in patients with paroxysmal atrial fibrillation: the randomized INDI-FREEZE trial“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren