Hemodynamic Assessment of Aortic Regurgitation after Transcatheter Aortic Valve Replacement: The Diastolic Pressure-Time Index

  • Robert Höllriegel*
  • , Felix Woitek
  • , Razvan Stativa
  • , Norman Mangner
  • , Stephan Haußig
  • , Georg Fuernau
  • , David Holzhey
  • , Friedrich W. Mohr
  • , Gerhard C. Schuler
  • , Axel Linke
  • *Korrespondierende/r Autor/-in für diese Arbeit
  • Universität Leipzig

Abstract

Objectives Assessment of aortic regurgitation (AR) immediately after transcatheter aortic valve replacement (TAVR) is essential to guide further intervention in cases of relevant AR. It was the aim of this study to identify a simple and reproducible hemodynamic parameter for the assessment of AR. Background Relevant AR after TAVR is present in up to 21% of cases and might be associated with adverse long-term outcomes. Methods Three hundred sixty-two consecutive patients who were treated with TAVR for symptomatic aortic valve stenosis were analyzed. AR was assessed by aortic root angiography according to the Sellers classification. For hemodynamic evaluation, the diastolic pressure-time (DPT) index was calculated after TAVR: the area between the aortic and left ventricular pressure-time curves was measured during diastole and divided by the duration of diastole to calculate the DPT index. The DPT index was finally adjusted for the respective systolic blood pressure: DPT indexadj = (DPT index/systolic blood pressure) × 100. Results Patients with angiographically nonrelevant AR (grade <2) had higher DPT indexadj (30.7 ± 6.8) compared with those with relevant AR (grade ≥2) (26.2 ± 5.8) (p < 0.05). Patients with DPT indexadj ≤27.9 had significantly higher 1-year mortality risk in comparison with those with DPT indexadj >27.9: 41.4% versus 13.5% (hazard ratio: 3.8; 95% confidence interval: 2.4 to 5.9; p [log rank-test] < 0.001). In multivariate regression analysis, DPT indexadj ≤27.9 was the strongest independent predictor of 1-year mortality (hazard ratio: 2.5; 95% confidence interval: 1.8 to 3.7; p < 0.001). Conclusions DPT indexadj is a simple, investigator-independent parameter that should be considered to differentiate between relevant and nonrelevant AR after TAVR.

OriginalspracheEnglisch
ZeitschriftJACC: Cardiovascular Interventions
Jahrgang9
Ausgabenummer10
Seiten (von - bis)1061-1068
Seitenumfang8
ISSN1936-8798
DOIs
PublikationsstatusVeröffentlicht - 23.05.2016

Fördermittel

grant support from Medtronic; and has received speaking honoraria from Edwards Lifesciences, Boston Scientific, and Symetis. Dr. Holzhey is a consultant to Medtronic and Symetis.

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen

Strategische Forschungsbereiche und Zentren

  • Forschungsschwerpunkt: Gehirn, Hormone, Verhalten - Center for Brain, Behavior and Metabolism (CBBM)

Fingerprint

Untersuchen Sie die Forschungsthemen von „Hemodynamic Assessment of Aortic Regurgitation after Transcatheter Aortic Valve Replacement: The Diastolic Pressure-Time Index“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren