Evaluation of the synthesis process of spions for mpi with different iron salts with mps

J. Schonvogel, K. Lüdtke-Buzug*

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

Tracers play a decisive role for the image quality in the MPI. The gold standard Resovist provides acceptable images, but not all of the iron in the Resovist contributes to signal generation. This results in a much higher amount of iron having to be injected into the organism than would be necessary for imaging. Iron is one of the essential trace elements, and it’s toxicity is expected to be low. However, tracer development should focus equally on improving image quality and reducing iron doses. This paper presents the standard method of co-precipitation with different iron salts. The different anions used have different ionic strengths and thus influence the crystal formation of the superparamagnetic magnetite.

OriginalspracheEnglisch
Aufsatznummer2009070
ZeitschriftInternational Journal on Magnetic Particle Imaging
Jahrgang6
Ausgabenummer2
Seiten (von - bis)1-3
Seitenumfang3
ISSN2365-9033
DOIs
PublikationsstatusVeröffentlicht - 02.09.2020

Strategische Forschungsbereiche und Zentren

  • Forschungsschwerpunkt: Biomedizintechnik

Fingerprint

Untersuchen Sie die Forschungsthemen von „Evaluation of the synthesis process of spions for mpi with different iron salts with mps“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren