Objective: To evaluate the performance characteristics of direct and capture ELISA for the detection of PR3-ANCA in Wegener's granulomatosis (WG) in international ANCA reference laboratories. Methods: Serum samples were derived from patients with histological and clinical diagnosis of WG (n=60), rheumatoid arthritis (RA) (n=30) and healthy controls (n=30). Each of them was tested for the presence of ANCA by indirect immunofluorescence technique (IFT), direct and capture ELISA in six international reference laboratories (Massachusetts General Hospital, Boston; Wieslab AB, Lund; University of Maastricht; University Hospital Groningen; Mayo Clinic, Rochester; Rheumaklinik Bad Bramstedt/University of Schleswig-Holstein Campus Lübeck). Each centre tested the sera according to their house protocols of IFT and ELISA. The diagnostic performance of each test was estimated by receiver operating characteristic curve analysis and sensitivity and specificity in detection of ANCA/PR3-ANCA were calculated for the respective methods. Results: In patients histologically and clinically known as WG, the detection of ANCA by IFT varied between 52 and 83% among the participating centres. PR3-ANCA positivity with the different ELISAs ranged from 53 to 80% in direct ELISA and from 72 to 76% in capture ELISA. While most capture ELISAs successfully detected PR3-ANCA, there were significant differences between IFT and direct ELISA results between laboratories. ROC curve analysis demonstrated that in five of six laboratories the overall diagnostic performance of capture ELISA was superior to IFT and direct ELISA, respectively. Conclusion: Capture ELISA is a highly sensitive assay for detection of PR3-ANCA in WG and should be used in conjunction with compatible clinical picture and histological evidence.

OriginalspracheEnglisch
ZeitschriftRheumatology
Jahrgang43
Ausgabenummer2
Seiten (von - bis)174-180
Seitenumfang7
ISSN1462-0324
DOIs
PublikationsstatusVeröffentlicht - 02.2004

Fördermittel

The authors would like to thank Monika Backes and Jos Austen for their excellent technical assistance. This study was supported by BMBF grant no. 01 G1 9951, Competence network systemic inflammatory rheumatic diseases.

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen

Strategische Forschungsbereiche und Zentren

  • Forschungsschwerpunkt: Infektion und Entzündung - Zentrum für Infektions- und Entzündungsforschung Lübeck (ZIEL)

Fingerprint

Untersuchen Sie die Forschungsthemen von „Evaluation of capture ELISA for detection of antineutrophil cytoplasmic antibodies directed against proteinase 3 in Wegener's granulomatosis: First results from a multicentre study“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren