Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Computed tomography hypoperfusion-hypodensity mismatch vs. automated perfusion mismatch to identify stroke patients eligible for thrombolysis

Peter B. Sporns, André Kemmling, Lennart Meyer*, Christos Krogias, Volker Puetz, Kolja M. Thierfelder, Marco Duering, Carsten Lukas, Daniel Kaiser, Sönke Langner, Alex Brehm, Lukas T. Rotkopf, Wolfgang G. Kunz, Carolin Beuker, Walter Heindel, Jens Fiehler, Peter Schramm, Heinz Wiendl, Heike Minnerup, Marios Nikos PsychogiosJens Minnerup

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

Background and purpose: Automated perfusion imaging can detect stroke patients with unknown time of symptom onset who are eligible for thrombolysis. However, the availability of this technique is limited. We, therefore, established the novel concept of computed tomography (CT) hypoperfusion-hypodensity mismatch, i.e., an ischemic core lesion visible on cerebral perfusion CT without visible hypodensity in the corresponding native cerebral CT. We compared both methods regarding their accuracy in identifying patients suitable for thrombolysis. Methods: In a retrospective analysis of the MissPerfeCT observational cohort study, patients were classified as suitable or not for thrombolysis based on established time window and imaging criteria. We calculated predictive values for hypoperfusion-hypodensity mismatch and automated perfusion imaging to compare accuracy in the identification of patients suitable for thrombolysis. Results: Of 247 patients, 219 (88.7%) were eligible for thrombolysis and 28 (11.3%) were not eligible for thrombolysis. Of 197 patients who were within 4.5 h of symptom onset, 190 (96.4%) were identified by hypoperfusion-hypodensity mismatch and 88 (44.7%) by automated perfusion mismatch (p < 0.001). Of 22 patients who were beyond 4.5 h of symptom onset but were eligible for thrombolysis, 5 patients (22.7%) were identified by hypoperfusion-hypodensity mismatch. Predictive values for the hypoperfusion-hypodensity mismatch vs. automated perfusion mismatch were as follows: sensitivity, 89.0% vs. 50.2%; specificity, 71.4% vs. 100.0%; positive predictive value, 96.1% vs. 100.0%; and negative predictive value, 45.5% vs. 20.4%. Conclusion: The novel method of hypoperfusion-hypodensity mismatch can identify patients suitable for thrombolysis with higher sensitivity and lower specificity than established techniques. Using this simple method might therefore increase the proportion of patients treated with thrombolysis without the use of special automated software. The MissPerfeCT study is a retrospective observational multicenter cohort study and is registered with clinicaltrials.gov (NCT04277728).

OriginalspracheEnglisch
Aufsatznummer1320620
ZeitschriftFrontiers in Neurology
Jahrgang14
ISSN1664-2295
DOIs
PublikationsstatusVeröffentlicht - 2023

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen

Strategische Forschungsbereiche und Zentren

  • Forschungsschwerpunkt: Biomedizintechnik

DFG-Fachsystematik

  • 2.23-07 Klinische Neurologie, Neurochirurgie und Neuroradiologie

Fingerprint

Untersuchen Sie die Forschungsthemen von „Computed tomography hypoperfusion-hypodensity mismatch vs. automated perfusion mismatch to identify stroke patients eligible for thrombolysis“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren