Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Complication Rates Observed in Silicone and Polyurethane Catheters of Totally Implanted Central Venous Access Devices Implanted in the Upper Arm

Jasmin D. Busch*, Maren Vens, Catherine Mahler, Jochen Herrmann, Gerhard Adam, Harald Ittrich

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

Purpose To present frequency and types of complications related to silicone (SI) versus polyurethane (PUR) catheters of totally implanted venous access devices (TIVADs) placed in the upper arm. Material and Methods A cohort of 2,491 consecutive patients with TIVADs implanted between 2006 and 2015 was retrospectively analyzed. Complications were classified according to SIR guidelines. Pearson χ2 test was used for categorical variables, and Student t test was used for continuous variables. Nominal P values were reported, and 2-sided P values <.05 were considered significant. Results Of 2,270 patients meeting the inclusion criteria, 538 had an SI catheter, and 1,732 had a PUR catheter. Total dwell time was 584,853 catheter days. Mean total complication rate was 12.25% (SI, 14.87%; PUR, 11.43%; P =.040). Subanalysis revealed significant differences for material failures (eg, catheter fracture [SI, 3.35%; PUR, 0.06%; P <.001] and thrombotic catheter occlusion/venous thromboses [SI, 2.79%/0.74%; PUR, 1.33%/3.17%; P <.001]) but nonsignificant differences for infections (eg, local infection and catheter-related sepsis [SI, 4.64%; PUR, 4.68%; P = 1]) or other nonthrombotic dysfunctions (eg, catheter detachment, line migration, wound dehiscence [SI, 3.35%; PUR, 2.19%; P =.179]). Conclusions The reported data suggest different risk profiles in SI catheters compared with PUR catheters, with more material failures and thrombotic catheter occlusions in SI catheters and more venous thromboses in PUR catheters.

OriginalspracheEnglisch
ZeitschriftJournal of Vascular and Interventional Radiology
Jahrgang28
Ausgabenummer8
Seiten (von - bis)1177-1183
Seitenumfang7
ISSN1051-0443
DOIs
PublikationsstatusVeröffentlicht - 08.2017

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen

Fingerprint

Untersuchen Sie die Forschungsthemen von „Complication Rates Observed in Silicone and Polyurethane Catheters of Totally Implanted Central Venous Access Devices Implanted in the Upper Arm“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren