Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Clinical experience with the ATS 3f Enable® Sutureless Bioprosthesis

Sven Martens, Jerzy Sadowski, Friedrich S. Eckstein, Krzysztof Bartus, Boguslaw Kapelak, Hans Hinrich Sievers, Christian Schlensak, Thierry Carrel

Abstract

Objective: The ATS 3f Enable®Bioprosthesis is a self-expanding valve with a tubular design that allows for decreased leaflet stress and preservation of aortic sinuses. We report the midterm results of a prospective, multicenter clinical study evaluating the safety and efficacy of this stented bioprosthesis in patients undergoing isolated aortic valve replacement with or without concomitant procedures. Methods: A total of 140 patients (mean age: 76±6years; 63% of patients in New York Heart Association (NYHA) stage III-IV) received the ATS 3f Enable®Bioprosthesis in 10 European centers between March 2007 and December 2009. The total accumulated follow-up is 121.8 patient-years. Results: Valve implantation resulted in significant improvement of patients' symptoms. Mean systolic gradient was 9.04±3.56 and 8.62±3.16mmHg with mean effective orifice area of 1.69±0.52 and 1.67±0.44 at 6 months and 1 year, respectively. No significant transvalvular aortic regurgitation was observed. Early complications included three major paravalvular leaks (PVL; 2.1%) resulting in valve explantation and one thrombo-embolic (0.7%) event. All, but one, of the early PVLs were evident intra-operatively with the medical decision made not to reposition or resolve immediately. Late adverse events included three explantations (2.5% per patient-year): one due to PVL and two due to endocarditis. There was an additional case of late endocarditis (0.8% per patient-year) that resolved by medical management. No structural deterioration, valve-related thrombosis or hemolysis was documented. Conclusions: The sutureless valve implantation technique is feasible and safe with the ATS 3f Enable Bioprosthesis. Valve implantation resulted in excellent hemodynamics and significant clinical improvement. Overall, these data confirm the safety and clinical utility of the Enable®Bioprosthesis for aortic valve replacement. © 2011 European Association for Cardio-Thoracic Surgery.
OriginalspracheEnglisch
TitelEuropean Journal of Cardio-thoracic Surgery
Seitenumfang7
Erscheinungsdatum09.2011
Seiten749-755
ISBN (Print)1873-734X (Electronic)\r1010-7940 (Linking)
DOIs
PublikationsstatusVeröffentlicht - 09.2011

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen

Fingerprint

Untersuchen Sie die Forschungsthemen von „Clinical experience with the ATS 3f Enable® Sutureless Bioprosthesis“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren