Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation

Buntaro Fujita*, Maximilian Kütting, Moritz Seiffert, Smita Scholtz, Sandrine Egron, Emir Prashovikj, Jochen Börgermann, Timm Schäfer, Werner Scholtz, Rainer Preuss, Jan Gummert, Ulrich Steinseifer, Stephan M. Ensminger

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

Aims New-onset conduction disturbances still represent a considerable problem after transcatheter aortic valve implantation (TAVI). The aim of this study was to identify calcification patterns with an elevated risk for permanent pacemaker implantation (PPI) after TAVI and investigate underlying mechanisms in an ex vivo setting Methods One hundred and sixty-two patients who underwent TAVI with the Edwards SAPIEN XTw or Medtronic CoreValvew and results at our institution were analysed. The calcium load of the device landing zone was quantified with 3mensiow, and calcium patterns with an elevated risk for PPI were identified. Ex vivo simulations of balloon valvuloplasty were performed in 3D-printed silicone annuli of patients matching the identified risk profile. Patients with a calcium load of the left coronary cusp (LCC) above 209 mm3 had a higher rate of PPI than patients below this threshold (16.7 vs. 2.6%, P ¼ 0.003). Multivariate regression revealed pre-existing right bundle branch block (RBBB) and increased LCC calcification as independent predictors for PPI. Simulation of the TAVI procedure in a silicone annulus revealed an off-centreline shift of the valvuloplasty balloon and transcatheter heart valve away from the LCC towards the commissure between right- and non-coronary cusp Conclusion Pre-existing RBBB and elevated LCC calcification were identified as independent predictors for PPI. These two risk factors enabled us to distinguish between patients according to their risk for PPI after TAVI. Ex vivo simulations suggested an off-centreline shift of the balloon as a possible explanation.

OriginalspracheEnglisch
ZeitschriftEuropean Heart Journal Cardiovascular Imaging
Jahrgang17
Ausgabenummer12
Seiten (von - bis)1385-1393
Seitenumfang9
ISSN2047-2404
DOIs
PublikationsstatusVeröffentlicht - 2016

Fördermittel

This work was supported by ADUMED-Stiftung.

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen

Fingerprint

Untersuchen Sie die Forschungsthemen von „Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren