Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation

Thomas Schlosser, Konstantin Pagonidis, Christoph U. Herborn, Peter Hunold, Kai Uwe Waltering, Thomas C. Lauenstein, Jörg Barkhausen*

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

OBJECTIVE. The purpose of our study was to quantify left ventricular function and mass derived from retrospectively ECG-gated 16-MDCT coronary angiography data sets using a new analysis software based on automatic contour detection in comparison to corresponding standard of reference measurements acquired with MRI. SUBJECTS AND METHODS. Multiplanar reformations in the short-axis orientation were calculated from axial contrast-enhanced CT images in 18 patients (men, 15; women, three; age range, 38-70 years; mean, 57.4 ± 10.2 [SD] years) who were referred for CT coronary angiography. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed with a recently developed imaging software using an automated contour detection algorithm of left ventricular endo- and epicardial contours and by manual tracing. The data were compared with similar measurements on MRI as the standard of reference. RESULTS. EDV, ESV, EF, and LVM derived from an automated contour detection algorithm were not statistically significantly different from manual tracing (CTauto vs CT manual: EDV = 137.1 ± 45.7 mL vs 134.2 ± 39.9 mL, ESV = 58.8 ± 34.2 mL vs 58.1 ± 30.1 mL, EF = 59.2% ± 13.7% vs 58.1% ± 12.0%, LVM = 130.9 ± 29.1 g vs 133.7 ± 33.2 g; p > 0.05). However, EDV (118.7 ± 43.6 mL), ESV (50.1 ± 33.5 mL), and LVM (142.8 ± 38.4 g) as calculated on MR data sets were statistically significantly different from those calculated on CT (p < 0.05), whereas MRI-based EF (59.9% ± 14.4%) did not differ statistically significantly from those based on both CT algorithms (p > 0.05). CONCLUSION. Automatic and manual analysis of data acquired during CT coronary angiography using a 16-MDCT scanner allows a reliable assessment of left ventricular ejection fraction and a rough estimation of left ventricular volumes and mass.

OriginalspracheEnglisch
ZeitschriftAmerican Journal of Roentgenology
Jahrgang184
Ausgabenummer3
Seiten (von - bis)765-773
Seitenumfang9
ISSN0361-803X
DOIs
PublikationsstatusVeröffentlicht - 01.01.2005

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen
  2. SDG 9 – Industrie, Innovation und Infrastruktur
    SDG 9 – Industrie, Innovation und Infrastruktur

Fingerprint

Untersuchen Sie die Forschungsthemen von „Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren