Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Acute kidney injury after transcatheter aortic valve implantation: Impact of contrast agents, predictive factors, and prognostic importance in 203 patients with long-term follow-up

Kenichi Chatani*, Mohamed Abdel-Wahab, Nora Wübken-Kleinfeld, Ken Gordian, Kathrin Pötzing, Ahmad E. Mostafa, Ernst Günter Kraatz, Doreen Richardt, Mohamed El-Mawardy, Gert Richardt

*Korrespondierende/r Autor/-in für diese Arbeit

Abstract

Background: Acute kidney injury (AKI) frequently occurs following transcatheter aortic valve implantation (TAVI) and has been related to a worse outcome. We investigated the importance of contrast medium composition, either iso-osmolar (IOCM) or low-osmolar (LOCM) and assessed predictors for AKI after TAVI. Methods and results: We assessed AKI in 203 TAVI patients treated mainly with trans-femoral implantation and analgosedation. A total of 100 patients received IOCM and 103 LOCM. AKI was defined according to the Valve Academic Research Consortium. Following TAVI, 39 patients (19.2%) developed AKI; 17.0% of the IOCM and 21.4% of the LOCM group (p=0.43). The only independent predictor for AKI was baseline serum creatinine [odds ratio (OR) 0.26, 95% confidence interval (CI) 0.01-0.64, p=0.002]. Patients with advanced AKI (stages 2 and 3) post-TAVI had significantly higher mortality at 2 years (log rank p<. 0.001), whereas patients with AKI stage 1 had a similar long-term outcome to non-AKI patients. Conclusions: Following TAVI, we observed no difference in the occurrence of AKI between IOCM and LOCM. Baseline creatinine was the only independent predictor of AKI, and patients who developed advanced AKI had significantly higher mortality at 2 years.

OriginalspracheEnglisch
ZeitschriftJournal of Cardiology
Jahrgang66
Ausgabenummer6
Seiten (von - bis)514-519
Seitenumfang6
ISSN0914-5087
DOIs
PublikationsstatusVeröffentlicht - 12.2015

Fördermittel

G. Richardt and M. Abdel-Wahab report receiving a research grant from Medtronic. All other authors do not report any conflict of interest in relation to the contents of this manuscript.

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gesundheit und Wohlergehen
    SDG 3 – Gesundheit und Wohlergehen

Fingerprint

Untersuchen Sie die Forschungsthemen von „Acute kidney injury after transcatheter aortic valve implantation: Impact of contrast agents, predictive factors, and prognostic importance in 203 patients with long-term follow-up“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren