TY - JOUR
T1 - A novel trileaflet mechanical heart valve: First in vitro results
AU - Schubert, Kathrin
AU - Schaller, Tim
AU - Stojenthin, Elisabeth
AU - Stephan, Christian
AU - Sievers, Hans Hinrich
AU - Scharfschwerdt, Michael
N1 - Funding Information:
This work was supported by the German Federal Ministry of Education and Research [grant number 13GW055B].
Publisher Copyright:
© 2018 The Author(s). Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Copyright:
Copyright 2019 Elsevier B.V., All rights reserved.
PY - 2018/12/24
Y1 - 2018/12/24
N2 - Objectives: Heart valve prostheses are the therapy of choice for patients with severe heart valve diseases. Two types of prostheses that can be implanted in patients are available: biological and mechanical. Though mechanical heart valves have some disadvantages like necessity of life-long anticoagulation, biological heart valve prostheses often necessitate reinterventions due to limited durability. Therefore, a new trileaflet mechanical heart valve was developed, featuring hinges in the systolic flow with the aim of function and thrombogenicity. Methods: We first compared the new trileaflet mechanical heart valve to conventional bileaflet heart valves (St. Jude Medical and On-X valves) in vitro. Haemodynamic measurements were performed in a pulse duplicator system, and clot formation was examined with an implemented method using enzyme-activated milk as the test medium. Results: Haemodynamic measurements showed the largest effective orifice areas and smallest pressure gradients for the trileaflet prosthesis compared to the bileaflet valve. Opening and closing characteristics of the trileaflet valve and of the St. Jude Medical valve were comparable. Clotting tests depicted only minor isolated deposits for the new trileaflet valve whereas the bileaflet valves showed distinct clots in the area of the hinge in all experiments. Conclusions: Haemodynamic and clotting tests showed improvements for the new trileaflet valve compared to common bileaflet valves. The off-wall systolic position of the hinges, which eluded adverse flow areas, was a major advantage of the new valve.
AB - Objectives: Heart valve prostheses are the therapy of choice for patients with severe heart valve diseases. Two types of prostheses that can be implanted in patients are available: biological and mechanical. Though mechanical heart valves have some disadvantages like necessity of life-long anticoagulation, biological heart valve prostheses often necessitate reinterventions due to limited durability. Therefore, a new trileaflet mechanical heart valve was developed, featuring hinges in the systolic flow with the aim of function and thrombogenicity. Methods: We first compared the new trileaflet mechanical heart valve to conventional bileaflet heart valves (St. Jude Medical and On-X valves) in vitro. Haemodynamic measurements were performed in a pulse duplicator system, and clot formation was examined with an implemented method using enzyme-activated milk as the test medium. Results: Haemodynamic measurements showed the largest effective orifice areas and smallest pressure gradients for the trileaflet prosthesis compared to the bileaflet valve. Opening and closing characteristics of the trileaflet valve and of the St. Jude Medical valve were comparable. Clotting tests depicted only minor isolated deposits for the new trileaflet valve whereas the bileaflet valves showed distinct clots in the area of the hinge in all experiments. Conclusions: Haemodynamic and clotting tests showed improvements for the new trileaflet valve compared to common bileaflet valves. The off-wall systolic position of the hinges, which eluded adverse flow areas, was a major advantage of the new valve.
UR - http://www.scopus.com/inward/record.url?scp=85067698698&partnerID=8YFLogxK
U2 - 10.1093/icvts/ivy337
DO - 10.1093/icvts/ivy337
M3 - Journal articles
C2 - 30590696
AN - SCOPUS:85067698698
SN - 1569-9293
VL - 28
SP - 689
EP - 694
JO - Interactive Cardiovascular and Thoracic Surgery
JF - Interactive Cardiovascular and Thoracic Surgery
IS - 5
ER -